EP2C5F256C6N Datasheet, PDF (78/168 Pages) Altera Corporation – Section I. Cyclone II Device Family Data Sheet | |||
|
◁ |
IEEE Std. 1149.1 (JTAG) Boundary Scan Support
The Cyclone II device instruction register length is 10 bits and the
USERCODE register length is 32 bits. Tables 3â2 and 3â3 show the
boundary-scan register length and device IDCODE information for
Cyclone II devices.
Table 3â2. Cyclone II Boundary-Scan Register Length
Device
EP2C5
EP2C8
EP2C15
EP2C20
EP2C35
EP2C50
EP2C70
Boundary-Scan Register Length
498
597
969
969
1,449
1,374
1,890
Table 3â3. 32-Bit Cyclone II Device IDCODE
Device
EP2C5
EP2C8
EP2C15
EP2C20
EP2C35
EP2C50
EP2C70
IDCODE (32 Bits) (1)
Version (4 Bits) Part Number (16 Bits) Manufacturer Identity (11 Bits)
0000
0000
0000
0000
0000
0000
0000
0010 0000 1011 0001
0010 0000 1011 0010
0010 0000 1011 0011
0010 0000 1011 0011
0010 0000 1011 0100
0010 0000 1011 0101
0010 0000 1011 0110
000 0110 1110
000 0110 1110
000 0110 1110
000 0110 1110
000 0110 1110
000 0110 1110
000 0110 1110
LSB (1 Bit) (2)
1
1
1
1
1
1
1
Notes to Table 3â3:
(1) The most significant bit (MSB) is on the left.
(2) The IDCODEâs least significant bit (LSB) is always 1.
For more information on the Cyclone II JTAG specifications, refer to the
DC Characteristics & Timing Specifications chapter in the Cyclone II Device
Handbook, Volume 1.
3â4
Cyclone II Device Handbook, Volume 1
Altera Corporation