English
Language : 

EPF10K50VQC240-3 Datasheet, PDF (53/128 Pages) Altera Corporation – Embedded Programmable Logic Device Family
FLEX 10K Embedded Programmable Logic Device Family Data Sheet
Table 29. 3.3-V Device Capacitance of EPF10K10A & EPF10K30A Devices Note (12)
Symbol
Parameter
Conditions
CIN
CINCLK
COUT
Input capacitance
Input capacitance on dedicated
clock pin
Output capacitance
VIN = 0 V, f = 1.0 MHz
VIN = 0 V, f = 1.0 MHz
VOUT = 0 V, f = 1.0 MHz
Min
Max Unit
8
pF
12
pF
8
pF
Table 30. 3.3-V Device Capacitance of EPF10K100A Devices Note (12)
Symbol
Parameter
Conditions
CIN
CINCLK
COUT
Input capacitance
VIN = 0 V, f = 1.0 MHz
Input capacitance on dedicated VIN = 0 V, f = 1.0 MHz
clock pin
Output capacitance
VOUT = 0 V, f = 1.0 MHz
Min
Max Unit
10
pF
15
pF
10
pF
Table 31. 3.3-V Device Capacitance of EPF10K250A Devices Note (12)
Symbol
Parameter
Conditions
Min
Max Unit
CIN
CINCLK
Input capacitance
VIN = 0 V, f = 1.0 MHz
Input capacitance on dedicated VIN = 0 V, f = 1.0 MHz
clock pin
10
pF
15
pF
COUT Output capacitance
VOUT = 0 V, f = 1.0 MHz
10
pF
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC voltage input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 5.75 V
for input currents less than 100 mA and periods shorter than 20 ns.
(3) Numbers in parentheses are for industrial-temperature-range devices.
(4) Maximum VCC rise time is 100 ms, and VCC must rise monotonically.
(5) FLEX 10KA device inputs may be driven before VCCINT and VCCIO are powered.
(6) Typical values are for T A = 25° C and VCC = 3.3 V.
(7) These values are specified under the Recommended Operating Conditions shown in Table 27 on page 51.
(8) The IOH parameter refers to high-level TTL, PCI, or CMOS output current.
(9) The IOL parameter refers to low-level TTL, PCI, or CMOS output current. This parameter applies to open-drain pins
as well as output pins.
(10) This value is specified for normal device operation. The value may vary during power-up.
(11) This parameter applies to all -1 speed grade commercial temperature devices and all -2 speed grade
industrial-temperature devices.
(12) Capacitance is sample-tested only.
Altera Corporation
53