English
Language : 

EPF10K100ARI240-3 Datasheet, PDF (49/128 Pages) Altera Corporation – Embedded Programmable Logic Device Family
FLEX 10K Embedded Programmable Logic Device Family Data Sheet
Table 24. EPF10K50V & EPF10K130V Device DC Operating Conditions Notes (6), (7)
Symbol
Parameter
Conditions
Min
Typ
V IH
V IL
V OH
V OL
II
IOZ
I CC0
High-level input voltage
2.0
Low-level input voltage
–0.5
3.3-V high-level TTL output
I OH = –8 mA DC (8)
2.4
voltage
3.3-V high-level CMOS output I OH = –0.1 mA DC (8)
voltage
VCCIO – 0.2
3.3-V low-level TTL output
voltage
I OL = 8 mA DC (9)
3.3-V low-level CMOS output I OL = 0.1 mA DC (9)
voltage
Input pin leakage current
Tri-stated I/O pin leakage
current
VI = 5.3 V to –0.3 V (10)
–10
VO = 5.3 V to –0.3 V (10)
–10
VCC supply current (standby) VI = ground, no load
0.3
VI = ground, no load (11)
10
Max Unit
5.75
V
0.8
V
V
V
0.45
V
0.2
V
10
µA
10
µA
10
mA
mA
Table 25. EPF10K50V & EPF10K130V Device Capacitance (12)
Symbol
Parameter
Conditions
Min
Max Unit
CIN
CINCLK
COUT
Input capacitance
Input capacitance on dedicated
clock pin
Output capacitance
VIN = 0 V, f = 1.0 MHz
VIN = 0 V, f = 1.0 MHz
VOUT = 0 V, f = 1.0 MHz
10
pF
15
pF
10
pF
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input voltage is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 5.75 V
for input currents less than 100 mA and periods shorter than 20 ns.
(3) Numbers in parentheses are for industrial-temperature-range devices.
(4) Maximum VCC rise time is 100 ms. VCC must rise monotonically.
(5) EPF10K50V and EPF10K130V device inputs may be driven before VCCINT and VCCIO are powered.
(6) Typical values are for T A = 25° C and VCC = 3.3 V.
(7) These values are specified under the EPF10K50V and EPF10K130V device Recommended Operating Conditions in
Table 23 on page 48.
(8) The IOH parameter refers to high-level TTL or CMOS output current.
(9) The IOL parameter refers to low-level TTL or CMOS output current. This parameter applies to open-drain pins as
well as output pins.
(10) This value is specified for normal device operation. The value may vary during power-up.
(11) This parameter applies to -1 speed grade EPF10K50V devices, -2 speed grade EPF10K50V industrial temperature
devices, and -2 speed grade EPF10K130V devices.
(12) Capacitance is sample-tested only.
Altera Corporation
49