English
Language : 

EV1380QI Datasheet, PDF (14/18 Pages) Enpirion, Inc. – 8a synchronous highly integrated dc-dc
Layout Recommendations
Figure 8 and Figure 9 shows critical
components along with top and bottom traces
of a recommended minimum footprint of the
EV1380QI layout with ENABLE tied to VIN.
Alternate ENABLE configurations and other
small signal pins need to be connected and
routed according to specific customer
application. Please see the Gerber files at
www.altera.com/enpirion for exact dimensions
and other layers. Please refer to Figures 8 and
9 while reading the layout recommendations in
this section.
Recommendation 1: Input and output filter
capacitors should be placed on the same side
of the PCB, and as close to the EV1380QI
package as possible. They should be
connected to the device with very short and
wide traces. Do not use thermal reliefs or
spokes when connecting the capacitor pads to
the respective nodes. The +V and GND traces
between the capacitors and the EV1380QI
should be as close to each other as possible
so that the gap between the two nodes is
minimized, even under the capacitors.
Recommendation 2: There are a total of
seven PGND pins dedicated to the input and
output circuits. The input and output ground
currents should be separated with a slit until
they reach the seven PGND pins to help
minimize noise coupling between the converter
input and output switching loops.
Recommendation 3: The system ground
plane should be the first layer immediately
below the surface layer. This ground plane
should be continuous and un-interrupted below
the converter and the input/output capacitors.
Please see the Gerber files at
www.altera.com/enpirion.
Recommendation 4: The large thermal pad
underneath the component must be connected
to the system ground plane through as many
vias as possible.
EV1380 Datasheet
Figure 8: Top PCB Layer with Critical
Components and Copper for
Minimum Footprint (Top View)
Figure 9: Bottom PCB Layer with Critical
Components and Copper for
Minimum Footprint (Top View)
08888
14
March 18, 2015
www.altera.com/enpirion
Rev C