English
Language : 

AK4618 Datasheet, PDF (46/60 Pages) Asahi Kasei Microsystems – 192kHz 24-bit 6ch/12ch Audio CODEC with Microphone Interface
[AK4618]
■ Serial Control Interface
I2C-bus Control Mode
The AK4618 supports the fast-mode I2C-bus (max: 400kHz).
1. WRITE Operations
Figure 40 shows the data transfer sequence of the I2C-bus mode. All commands are preceded by a START condition. A
HIGH to LOW transition on the SDA line while SCL is HIGH indicates a START condition (Figure 46). After the
START condition, a slave address is sent. This address is 7 bits long followed by the eighth bit that is a data direction bit
(R/W). The most significant seven bits of the slave address are fixed as “0010000” (Figure 41). If the slave address
matches that of the AK4618, the AK4618 generates an acknowledge and the operation is executed. The master must
generate the acknowledge-related clock pulse and release the SDA line (HIGH) during the acknowledge clock pulse
(Figure 47). R/W bit = “1” indicates that the read operation is to be executed. “0” indicates that the write operation is to be
executed.
The second byte consists of the control register address of the AK4618. The format is MSB first, and those most
significant 3-bits are fixed to zeros (Figure 42). The data after the second byte contains control data. The format is MSB
first, 8bits (Figure 43). The AK4618 generates an acknowledge after each byte is received. Data transfer is always
terminated by a STOP condition generated by the master. A LOW to HIGH transition on the SDA line while SCL is HIGH
defines STOP condition (Figure 46).
The AK4618 can perform more than one byte write operation per sequence. After receipt of the third byte the AK4618
generates an acknowledge and awaits the next data. The master can transmit more than one byte instead of terminating the
write cycle after the first data byte is transferred. After receiving each data packet the internal 6-bit address counter is
incremented by one, and the next data is automatically taken into the next address. If the address exceeds 16H prior to
generating a stop condition, the address counter will “roll over” to 00H and the previous data will be overwritten.
The data on the SDA line must remain stable during the HIGH period of the clock. The HIGH or LOW state of the data
line can only change when the clock signal on the SCL line is LOW (Figure 48) except for the START and STOP
conditions.
S
T
S
A
R/W="0"
T
R
O
T
P
SDA
S lave
S Address
S ub
A ddress(n)
Data(n)
Data(n+1)
Data(n+x)
P
A
A
A
A
A
A
C
C
C
C
C
C
K
K
K
K
K
K
Figure 40. Data Transfer Sequence at the I2C-Bus Mode
0
0
1
0
0
0
0
R/W
Figure 41. The First Byte
0
0
0
A4
A3
A2
A1
A0
Figure 42. The Second Byte
D7
D6
D5
D4
D3
D2
D1
D0
Figure 43. Byte Structure after the second byte
015000617-E-00
- 46 -
2015/01