X9258 Datasheet, PDF (15/22 Pages) Xicor Inc. – Quad Digital Controlled Potentiometers (XDCP)
X9258
DCP TIMING
Symbol
tWRPO
tWRL
tWRID
Parameter
Wiper response time after the third (last) power supply is stable
Wiper response time after instruction issued (all load instructions)
Wiper response time from an active SCL/SCK edge (increment/decrement instruction)
Min.
Max.
10
10
10
Unit
µs
µs
µs
Note: (8) A device must internally provide a hold time of at least 300ns for the SDA signal in order to bridge the undefined region of the falling
edge of SCL.
TIMING DIAGRAMS 2-WIRE INTERFACE
START and STOP Timing
SCL
tSU:STA
SDA
(START)
tR
tHD:STA
tR
tF
tSU:STO
tF
(STOP)
Input Timing
tCYC
SCL
SDA
Output Timing
SCL
tSU:DAT
tHIGH
tLOW
tHD:DAT
tBUF
SDA
tAA
tDH
REV 1.1.7 2/4/03