English
Language : 

W83195WG-382 Datasheet, PDF (13/27 Pages) Winbond – Winbond Clock Generator
W83195WG-382/W83195CG-382
5 WD_TIMEOUT
4 SAF_FREQ<4>
3 SAF_FREQ<3>
2 SAF_FREQ<2>
1 SAF_FREQ<1>
0 SAF_FREQ<0>
STEPLESS FOR ATI K8 CLOCK GENERATOR
Read Back only. Timeout Flag.
0 1 : Watchdog has ever started and count to zero.
0 : a.) Watchdog is restarted and counting.
R
b.) Power on default state
0
0
These bits will be reloaded in Reg-0 to select
0 frequency table. As the watchdog is timeout and R/W
EN_SAFE_FREQ=1.
1
0
7.7 Register 6: ( Default : FFh )
AFFECTED PIN/
BIT
PWD
FUNCTION NAME(S)
FUNCTION DESCRIPTION
7 SRCEN<7>
SRC7 output control
1 1: Enable
0: Disable
6 SRCEN<6>
SRC6 output control
1 1: Enable
0: Disable
5 SRCEN<5>
SRC5 output control
1 1: Enable
0: Disable
4 SRCEN<4>
SRC4 output control
1 1: Enable
0: Disable
3 SRCEN<3>
2 ATIGEN<1>
1 ATIGEN<0>
SRC3 output control
1 1: Enable
0: Disable
ATIG1 output control
1
1: Enable
0: Disable
ATI clock can’t be controlled by CLKREQ# pins
ATIG0 output control
1
1: Enable
0: Disable
ATI clock can’t be controlled by CLKREQ# pins
0 SRCEN<0>
SRC0 output control
1 1: Enable
0: Disable
TYPE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Publication Release Date: Feb 2006
-9-
Revision 0.6