English
Language : 

DG411LE Datasheet, PDF (4/17 Pages) Vishay Siliconix – Low Parasitic Capacitance and Leakage, Quad SPST Switches
www.vishay.com
DG411LE, DG412LE, DG413LE
Vishay Siliconix
SPECIFICATIONS a (Dual Supply ± 5 V)
PARAMETER
Analog Switch
Analog Signal Range e
Drain-Source
On-Resistance
SYMBOL
TEST CONDITIONS
UNLESS OTHERWISE
SPECIFIED
V+ = 5 V, V- = -5 V
VL = 5 V, VIN = 2.4 V, 0.8 V f
A SUFFIX
D SUFFIX
LIMITS
LIMITS
TEMP.b TYP. c -55 °C to +125 °C -40 °C to +85 °C UNIT
MIN. d MAX. d MIN. d MAX. d
VANALOG
Full
-
-5
5
-5
5
V
RDS(on)
V+ = 5 V, V- = -5 V,
IS = 10 mA, VD = ± 3.5 V
Room 18
Full
-
-
-
30
42
-
30

-
37
Switch Off
Leakage Current g
IS(off)
ID(off)
Room
-
V+ = 5.5, V- = -5.5 V,
Full
-
VD = ± 4.5 V, VS = ± 4.5 V
Room
-
Full
-
-1
1
-1
1
-15
15
-10
10
-1
1
-1
1
nA
-15
15
-10
10
Channel On 
Leakage Current g
ID(on)
V+ = 5.5 V, V- = -5.5 V,
VS = VD = ± 4.5 V
Room
-
Full
-
-1
1
-1
1
-15
15
-10
10
Digital Control
Input Current, VIN Low e
IIL
Input Current, VIN High e
IIH
Dynamic Characteristics
VIN under test = 0.8 V
VIN under test = 2.4 V
Full
0.05 -1.5
1.5
-1
Full
0.05 -1.5
1.5
-1
1
μA
1
Turn-On Time e
Turn-Off Time e
Room 17
-
50
-
50
tON
RL = 300, CL = 35 pF,
Full
-
-
70
-
60
tOFF
VS = ± 3.5 V, see figure 2
Room 12
-
35
-
35
ns
Full
-
-
50
-
40
Break-Before-Make Time
Delay e
tD
DG413L only, VS = 3.5 V,
RL = 300, CL = 35 pF
Room
5
-
-
-
-
Charge Injection e
Q
Vg = 0 V, Rg = 0 , CL = 10 nF Room 5.8
-
-
-
-
pC
Off Isolation e
OIRR
Room 68
-
-
-
-
Channel-to-Channel
Crosstalk e
XTALK
RL = 50 , CL = 5 pF, f = 1 MHz Room
113
-
-
dB
-
-
Source Off Capacitance e
CS(off)
Room
5
-
-
-
-
Drain Off Capacitance e
Channel On Capacitance e
CD(off)
CD(on)
f = 1 MHz
Room
6
-
-
-
-
pF
Room 14
-
-
-
-
Power Supplies
Positive Supply Current e
I+
Room 0.03
-
1
-
1
Full
-
-
7.5
-
5
Negative Supply Current e
I-
Logic Supply Current e
IL
VIN = 0 V or 5 V
Room -0.002 -1
-
-1
Full
-
-7.5
-
-5
Room 0.002
-
1
-
Full
-
-
7.5
-
-
-
μA
1
5
Ground Current e
IGND
Room -0.002 -1
-
-1
-
Full
-
-7.5
-
-5
-
Notes
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this datasheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. Leakage parameters are guaranteed by worst case test conditions and not subject to test.
S16-0391-Rev. A, 07-Mar-16
4
Document Number: 78091
For technical questions, contact: analogswitchsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000