BFC3366Y2 Datasheet, PDF (4/12 Pages) Vishay Siliconix – Interference Suppression Film Capacitors MKP Radial Potted Type
Not for New Design - Please refer to MKP338 6 Y2 (28114)
www.vishay.com
MKP336 6 Y2
Vishay BCcomponents
APPROVALS
SAFETY APPROVALS Y2
VOLTAGE
VALUE
FILE NUMBERS
EN132400
300 VAC
1 nF to 47 nF
FI 2008059
UL 60384-14
300 VAC
1 nF to 47 nF
E354331
CSA-E384-14
300 VAC
1 nF to 47 nF
E354331
CB-test-certificate
300 VAC
1 nF to 47 nF
FI 5255 A2
The ENEC-approval together with the CB-certificate replace all national marks of the following countries (they have already signed the
ENEC-agreement): Austria; Belgium; Czech. Republic; Denmark; Finland; France; Germany; Greece; Hungary; Ireland; Italy; Luxembourg;
Netherlands; Norway; Portugal; Slovenian; Spain; Switzerland and United Kingdom.
MOUNTING
Normal Use
The capacitors are designed for mounting on printed-circuit boards. The capacitors packed in bandoliers are designed for
mounting in printed-circuit boards by means of automatic insertion machines.
For detailed tape specifications refer to packaging information: www.vishay.com/doc?28139
Specific Method of Mounting to Withstand Vibration and Shock
In order to withstand vibration and shock tests, it must be ensured that the stand-off pips are in good contact with the
printed-circuit board:
• The capacitors shall be mechanically fixed by the leads
Space Requirements on Printed Circuit Board
The maximum space for length (Imax.), width (wmax.) and height (hmax. ) of film capacitors to take in account on the printed circuit
board is shown in the drawings.
• For products with pitch  15 mm, w = l = 0.3 mm; h = 0.1 mm
Eccentricity defined as in drawing. The maximum eccentricity is smaller than or equal to the lead diameter of the product
concerned.
Eccentricity
wmax. = W + Δ
Imax. = I + Δ
CBA116
hmax. = h + Δ
Seating plane
SOLDERING CONDITIONS
For general soldering conditions and wave soldering profile, we refer to the application note:
“Soldering Guidelines for Film Capacitors”: www.vishay.com/doc?28171
Storage Temperature
Tstg = - 25 °C to + 35 °C with RH maximum 75 % without condensation
Ratings and Characteristics Reference Conditions
Unless otherwise specified, all electrical values apply to an ambient temperature of 23 °C ± 1 °C, an atmospheric pressure of
86 kPa to 106 kPa and a relative humidity of 50 % ± 2 %.
For reference testing, a conditioning period shall be applied over 96 h ± 4 h by heating the products in a circulating air oven at
the rated temperature and a relative humidity not exceeding 20 %.
Revision: 11-Dec-12