SPECIFICATIONS TJ = 25 °C, unless otherwise noted
Parameter
Symbol
Test Conditions
Min
Static
Drain-Source Breakdown Voltage
VDS
VGS = 0 V, ID = - 250 µA
- 80
VDS Temperature Coefficient
VGS(th) Temperature Coefficient
ΔVDS/TJ
ΔVGS(th)/TJ
ID = - 250 µA
Gate-Source Threshold Voltage
VGS(th)
VDS = VGS, ID = - 250 µA
-2
Gate-Source Leakage
IGSS
VDS = 0 V, VGS = ± 20 V
Zero Gate Voltage Drain Current
On-State Drain Currenta
IDSS
ID(on)
VDS = - 80 V, VGS = 0 V
VDS = - 80 V, VGS = 0 V, TJ = 55 °C
VDS ≥ 5 V, VGS = - 10 V
Drain-Source On-State Resistancea
Forward Transconductancea
rDS(on)
gfs
VGS = - 10 V, ID = - 12.9 A
VDS = - 15 V, ID = - 12.9 A
Dynamicb
Input Capacitance
Ciss
Output Capacitance
Coss
VDS = - 40 V, VGS = 0 V, f = 1 MHz
Reverse Transfer Capacitance
Crss
Total Gate Charge
Qg
Gate-Source Charge
Qgs
VDS = - 40 V, VGS = - 10 V, ID = - 12.9 A
Gate-Drain Charge
Qgd
Gate Resistance
Rg
f = 1 MHz
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = - 40 V, RL = 3.7 Ω
ID ≅ - 10.8 A, VGEN = - 10 V, Rg = 1 Ω
Fall Time
tf
Drain-Source Body Diode Characteristics
Continuous Source-Drain Diode Current
IS
Pulse Diode Forward Currenta
ISM
TC = 25 °C
Body Diode Voltage
VSD
IS = - 10.8 A
Body Diode Reverse Recovery Time
trr
Body Diode Reverse Recovery Charge
Reverse Recovery Fall Time
Qrr
ta
IF = - 10.8 A, di/dt = 100 A/µs, TJ = 25 °C
Reverse Recovery Rise Time
tb
Notes:
a. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %.
b. Guaranteed by design, not subject to production testing.
Typ
Max
Unit
- 80
7.5
-3
0.022
39
V
mV/°C
-4
V
± 100
nA
-1
µA
- 10
A
0.026
Ω
S
5160
320
pF
220
102
155
22
nC
29
4
Ω
15
25
50
75
ns
90
135
65
100
- 50
A
- 60
- 0.8
- 1.2
V
60
90
ns
150
235
nC
45
ns
15
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
2
Document Number: 73442
S-71661-Rev. B, 06-Aug-07