English
Language : 

10-FY12M3A040SH-M749F08 Datasheet, PDF (1/26 Pages) Vincotech – 3 phase mixed voltage component topology
flow3xMNPC 1
Features
● 3 phase mixed voltage component topology
● neutral point clamped inverter
● reactive power capability
● low inductance layout
Target Applications
● solar inverter
● UPS
Types
● 10-FY12M3A040SH-M749F08
● 10-F112M3A040SH-M749F09
10-FY12M3A040SH-M749F08
10-F112M3A040SH-M749F09
1200V/40A
flow1 housing
12 mm
Schematic
17 mm
Tj=25°C, unless otherwise specified
Parameter
Half Bridge IGBT
Collector-emitter break down voltage
DC collector current
Pulsed collector current
Power dissipation per IGBT
Turn off safe operating area
Short circuit ratings
Gate-emitter peak voltage
Maximum Junction Temperature
Neutral Point FWD
Peak Repetitive Reverse Voltage
DC forward current
Surge forward current
Power dissipation per Diode
Maximum Junction Temperature
Maximum Ratings
Symbol
Condition
VCE
IC
ICpulse
Ptot
IC
tSC
VCC
VGE
Tjmax
Tj=Tjmax
tp limited by Tjmax
Tj=Tjmax
Tj≤150°C
Tj≤150°C
VGE=15V
V CE<=VCES
Th=80°C
Tc=80°C
Th=80°C
Tc=80°C
VRRM
IF
IFSM
Ptot
Tjmax
Tj=Tjmax
tp limited by Tjmax
Tj=Tjmax
Th=80°C
Tc=80°C
Th=80°C
Tc=80°C
Value
Unit
1200
V
31
A
41
120
A
75
W
114
120
A
10
µs
800
V
±20
A
175
°C
600
V
18
A
26
300
A
30
W
45
150
°C
copyright Vincotech
1
Revision: 3