BCM6123x60E15A3yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection SECONDARY to PRIMARY (Reverse Direction)
Effective Primary Output
Capacitance (External)
CPRI_OUT_EXT
Excessive capacitance may drive module into SC
protection
100
µF
Secondary Overvoltage Lockout
Threshold
VSEC_OVLO+ Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
16
16.5
17.3
V
Secondary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
Secondary Undervoltage Lockout
Threshold
VSEC_UVLO- Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
6.5
7
7.5
V
Secondary Undervoltage Lockout
Response Time
tSEC_UVLO
100
µs
Primary Undervoltage Lockout
Threshold
Applies only to reversilbe products in forward and in
VPRI_UVLO-_R reverse direction; IPRI_DC ≤ 20 while VPRI_UVLO-_R
26
28
30
< VPRI_DC < VPRI_MIN
V
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+_R
Applies only to reversilbe products in forward and in
reverse direction;
28
30
32
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST_R
Applies only to reversilbe products in forward and in
reverse direction;
2
V
Primary Output Overcurrent Trip
Threshold (Analog)
IPRI_OUT_OCP Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
36.25
45
56.25
A
Primary Output Overcurrent
Response Time Constant (Analog)
tPRI_OUT_OCP Effective internal RC filter
3
ms
Primary Short Circuit Protection Trip
Threshold
IPRI_SCP
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
48.75
A
Primary Short Circuit Protection
Response Time
tPRI_SCP
1
µs
Primary Output Overcurrent Trip
Threshold (PM Bus)
IPRI_OUT_OCP Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
41
44
47
A
Primary Output Overcurrent
Response Time Constant (PM Bus)
tPRI_OUT_OCP Effective internal RC filter
3
ms
BCM® Bus Converter
Page 9 of 28
Rev 1.2
07/2016
vicorpower.com
800 927.9474