English
Language : 

BCM6123E60E15A3T00 Datasheet, PDF (19/28 Pages) Vicor Corporation – BCM® Bus Converter
BCM6123x60E15A3yzz
General Characteristics
Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Length
Width
Height
Volume
Weight
Lead finish
Operating Temperature
Thermal Resistance Top Side
Thermal Resistance Leads
Thermal Resistance Bottom Side
Thermal Capacity
Storage temperature
ESD Withstand
L
W
H
Vol
W
TINTERNAL
ΦINT-TOP
Mechanical
60.87 / [2.396] 61.00 / [2.402] 61.13 / [2.407] mm/[in]
24.76 / [0.975] 25.14 / [0.990] 25.52 / [1.005] mm/[in]
Without Heatsink
7.21 / [0.284] 7.26 / [0.286] 7.31 / [0.288] mm/[in]
11.13 / [0.679]
cm3/[in3]
41 / [1.45]
g/[oz]
Nickel
0.51
2.03
Palladium
0.02
0.15
µm
Gold
0.003
0.051
Thermal
BCM6123x60E15A3yzz (T-Grade)
-40
125
°C
Estimated thermal resistance to maximum
temperature internal component from
1.26
isothermal top
°C/W
Estimated thermal resistance to
ΦΦINT-LEADS maximum temperature internal
component from isothermal leads
1.21
°C/W
Estimated thermal resistance to
ΦΦINT-BOTTOM maximum temperature internal
component from isothermal bottom
1.03
°C/W
34
Assembly
BCM6123x60E15A3yzz (T-Grade)
-55
125
ESDHBM
ESDCDM
Human Body Model, “ESDA / JEDEC JDS-001-2012” Class I-C (1kV to < 2kV)
Charge Device Model, “JESD 22-C101-E” Class II (200V to < 500V)
Ws/°C
°C
BCM® Bus Converter
Page 19 of 28
Rev 1.2
07/2016
vicorpower.com
800 927.9474