English
Language : 

BCM6123E60E15A3T00 Datasheet, PDF (4/28 Pages) Vicor Corporation – BCM® Bus Converter
BCM6123x60E15A3yzz
Part Ordering Information
Product
Function
Package
Size
Package
Mounting
Max Primary
Input Voltage
Range
Identifier
Max
Secondary
Voltage
Secondary
Output
Current
Temperature
Grade
Option
BCM
6123
x
60
E
15
A3
y
zz
Bus Converter 61 = L
Module
23 = W
T = TH
S = SMT
00 = Analog Ctrl
60V
36 – 60V
15V
No Load
130A
T = -40°C – 125°C
01 = PMBus Ctrl
M = -55°C – ­125°C 0R = Reversible Analog Ctrl
0P = Reversible PMBus Ctrl
All products shipped in JEDEC standard high profile (0.400” thick) trays (JEDEC Publication 95, Design Guide 4.10).
Standard Models
Product
Function
Package Package Max Primary
Size Mounting Input Voltage
BCM
6123
T
60
Range
Identifier
E
Max
Secondary
Voltage
Secondary
Output
Current
Temperature
Grade
15
A3
T
BCM
6123
T
60
E
15
A3
T
Option
00
01
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
+VPRI_DC to –VPRI_DC
VPRI_DC or VSEC_DC slew rate
(operational)
+VSEC_DC to –VSEC_DC
TM / SER-OUT to –VPRI_DC
EN to –VPRI_DC
VAUX / SER-IN to –VPRI_DC
Comments
Min
Max
Unit
-1
80
V
1
V/µs
-1
20
V
4.6
V
-0.3
5.5
V
4.6
V
BCM® Bus Converter
Page 4 of 28
Rev 1.2
07/2016
vicorpower.com