English
Language : 

BCM6123E60E15A3T00 Datasheet, PDF (12/28 Pages) Vicor Corporation – BCM® Bus Converter
BCM6123x60E15A3yzz
Analog Control Signal Characteristics (Cont.)
Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Auxiliary Voltage Source
• The VAUX pin is a standard analog I/O configured as an output from an internal µC.
• VAUX is internally connected to µC output as internally pulled high to a 3.3V regulator with 2% tolerance, a 1% resistor of 1.5kΩ.
• VAUX can be used as a “Ready to process full power” flag. This pin transitions VAUX voltage after a 2ms delay from the start of powertrain activating,
signaling the end of softstart.
• VAUX can be used as “Fault flag”. This pin is pulled low internally when a fault protection is detected.
SIGNAL TYPE
STATE
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN TYP MAX UNIT
Startup
Powertrain ­active to VAUX
time
tVAUX
Powertrain active to VAUX High
2
ms
VAUX Voltage
VVAUX
2.8
3.3 V
VAUX Available Current
IVAUX
4 mA
ANALOG
OUTPUT
Regular
Operation
VAUX Voltage Ripple
VAUX Capacitance
(External)
VVAUX_PP
CVAUX_EXT
TINTERNAL ≤ 100ºC
50
mV
100
0.01 µF
VAUX Resistance (External) RVAUX_EXT VPRI_DC < VµC_ACTIVE
1.5
kΩ
Fault
VAUX Fault Response Time tVAUX_FR From fault to VVAUX = 2.8V, CVAUX = 0pF
10
µs
BCM® Bus Converter
Page 12 of 28
Rev 1.2
07/2016
vicorpower.com
800 927.9474