English
Language : 

BCM6123E60E15A3T00 Datasheet, PDF (8/28 Pages) Vicor Corporation – BCM® Bus Converter
BCM6123x60E15A3yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
General Powetrain SECONDARY to PRIMARY Specification (Reverse Direction)
Secondary Input Voltage range,
continuous
VSEC_DC
9
15
V
VSEC_DC = 13.5V, TINTERNAL = 25ºC
14.7
21.6
SEC to PRI No Load Power
Dissipation
PSEC_NL
VSEC_DC = 13.5V
VSEC_DC = 9V to 15V, TINTERNAL = 25ºC
7
35.2
W
25
VSEC_DC = 9V to 15V
38
DC Secondary Input Current
ISEC_IN_DC
At IPRI_DC = 32.5A, TINTERNAL ≤ 100ºC
132.5
A
Primary Output Current (continuous)
Primary Output Current (pulsed)
IPRI_OUT_DC
IPRI_OUT_PULSE
10ms pulse, 25% Duty cycle,
IPRI_OUT_AVG ≤ 50% rated IPRI_OUT_DC
VSEC_DC = 13.5V, IPRI_OUT_DC = 32.5A
32.5
A
39
A
96.2
97.0
SEC to PRI Efficiency (ambient)
hAMB
VSEC_DC = 9V to 15V, IPRI_OUT_DC= 32.5A
95.2
%
VSEC_DC = 13.5V, IPRI_OUT_DC = 16.25A
96.5
97.4
SEC to PRI Efficiency (hot)
SEC to PRI Efficiency
(over load range)
SEC to PRI Output Resistance
ηhHOT
ηh20%
RPRI_COLD
RPRI_AMB
VSEC_DC = 13.5V, IPRI_OUT_DC = 32.5A
6.5A < IPRI_OUT_DC < 32.5A
VSEC_DC = 13.5V, IPRI_OUT_DC = 32.5A,
TINTERNAL = -40°C
VSEC_DC = 13.5V, IPRI_OUT_DC = 32.5A
95.8
96.5
%
92
%
25
30
35
31
38
45
mΩ
Primary Output Voltage Ripple
RPRI_HOT
VSEC_DC = 13.5V, IPRI_OUT_DC = 32.5A, TINTERNAL = 100°C
41
47
53
VPRI_OUT_PP
CPRI_OUT_EXT = 0μF, IPRI_OUT_DC = 32.5A,
VSEC_DC = 13.5V, 20MHz BW
TINTERNAL ≤ 100ºC
500
mV
1000
BCM® Bus Converter
Page 8 of 28
Rev 1.2
07/2016
vicorpower.com
800 927.9474