English
Language : 

BCM6123E60E15A3T00 Datasheet, PDF (5/28 Pages) Vicor Corporation – BCM® Bus Converter
BCM6123x60E15A3yzz
Electrical Specifications
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
General Powetrain PRIMARY to SECONDARY Specification (Forward Direction)
Primary Input Voltage range,
continuous
VPRI_DC
36
VPRI µController
VµC_ACTIVE
VPRI_DC voltage where µC is initialized,
(ie VAUX = Low, powertrain inactive)
PRI to SEC Input Quiescent Current
IPRI_Q
Disabled, EN Low, VPRI_DC = 54V
TINTERNAL ≤ 100ºC
VPRI_DC = 54V, TINTERNAL = 25ºC
PRI to SEC No Load Power
Dissipation
PPRI_NL
VPRI_DC = 54V
VPRI_DC = 36V to 60V, TINTERNAL = 25 ºC
7
PRI to SEC Inrush Current Peak
IPRI_INR_PK
VPRI_DC = 36V to 60V
VPRI_DC = 60V, CSEC_EXT = 3000μF, RLOAD_SEC = 20% of
full load current
TINTERNAL ≤ 100ºC
DC Primary Input Current
IPRI_IN_DC
At ISEC_OUT_DC = 130A, TINTERNAL ≤ 100ºC
Transformation Ratio
Secondary Output Current
(continuous)
K
ISEC_OUT_DC
Primary to secondary, K = VSEC_DC / VPRI_DC, at no load
Secondary Output Current (pulsed)
ISEC_OUT_PULSE
10ms pulse, 25% Duty cycle, ISEC_OUT_AVG ≤ 50% rated
ISEC_OUT_DC
VPRI_DC = 54V, ISEC_OUT_DC = 130A
96.2
PRI to SEC Efficiency (ambient)
ηhAMB
VPRI_DC = 36V to 60V, ISEC_OUT_DC = 130A
VPRI_DC = 54V, ISEC_OUT_DC = 65A
95.2
96.5
PRI to SEC Efficiency (hot)
PRI to SEC Efficiency
(over load range)
hHOT
ηh20%
VPRI_DC = 54V, ISEC_OUT_DC = 130A
26A < ISEC_OUT_DC < 130A
95.8
90
RSEC_COLD
VPRI_DC = 54V, ISEC_OUT_DC = 130A, TINTERNAL = -40°C
1.2
PRI to SEC Output Resistance
RSEC_AMB
VPRI_DC = 54V, ISEC_OUT_DC = 130A
1.6
RSEC_HOT
VPRI_DC = 54V, ISEC_OUT_DC = 130A, TINTERNAL = 100°C
2.2
Switching Frequency
FSW
Frequency of the Output Voltage Ripple = 2x FSW
0.9
Secondary Output Voltage Ripple
VSEC_OUT_PP
CSEC_EXT = 0μF, ISEC_OUT_DC = 130A, VPRI_DC = 54V,
20MHz BW
TINTERNAL ≤ 100ºC
Primary Input Leads Inductance
(Parasitic)
LPRI_IN_LEADS
Frequency 2.5MHz (double switching frequency),
Simulated lead model
Secondary Output Leads Inductance
(Parasitic)
LSEC_OUT_LEADS
Frequency 2.5MHz (double switching frequency),
Simulated lead model
5
14.7
40
1/4
97
97.4
96.5
1.5
1.95
2.5
0.95
120
6.7
0.64
60
14
10
21.6
35.2
25
38
45
33
130
145
1.8
2.3
2.8
1.0
250
V
V
mA
W
A
A
V/V
A
A
%
%
%
mΩ
MHz
mV
nH
nH
BCM® Bus Converter
Page 5 of 28
Rev 1.2
07/2016
vicorpower.com
800 927.9474