English
Language : 

BCM6123XD1E5126YZZ Datasheet, PDF (8/30 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Powertrain Supervisory Limits PRIMARY to SECONDARY (Forward Direction)
Primary Overvoltage Lockout
Threshold
VPRI_OVLO+
420
434.5
450
V
Primary Overvoltage Recovery
Threshold
VPRI_OVLO-
405
424
440
V
Primary Overvoltage Lockout
Hysteresis
VPRI_OVLO_HYST
10.5
V
Primary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
Primary Undervoltage Lockout
Threshold
VPRI_UVLO-
220
235
250
V
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+
230
245
260
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST
10
V
Primary Undervoltage Lockout
Response Time
tPRI_UVLO
100
µs
From VPRI_DC = VPRI_UVLO+ to powertrain active, EN
Primary Undervoltage Startup Delay tPRI_UVLO+_DELAY floating, (i.e One time Startup delay from application
20
ms
of VPRI_DC to VSEC_DC)
Secondary Output Overcurrent Trip
Threshold
ISEC_OUT_OCP
28
37
50
A
Secondary Output Overcurrent
Response Time Constant
tSEC_OUT_OCP Effective internal RC filter
3.2
ms
Overtemperature Shutdown
Threshold
tOTP+
Temperature sensor located inside controller IC
125
°C
Overtemperature Recovery
Threshold
tOTP–
105
110
115
°C
Undertemperature Shutdown
Threshold
tUTP
Temperature sensor located inside controller IC;
Protection not available for M-Grade units.
-45
°C
Undertemperature Restart Time
tUTP_RESTART
Startup into a persistent fault condition. Non-Latching
fault detection given VPRI_DC > VPRI_UVLO+
3
s
BCM® Bus Converter
Page 8 of 30
Rev 1.1
01/2017
vicorpower.com
800 927.9474