English
Language : 

BCM6123XD1E5126YZZ Datasheet, PDF (10/30 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection SECONDARY to PRIMARY (Reverse Direction)
Secondary Overvoltage Lockout
Threshold
VSEC_OVLO+ Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
52.5
54.5
56.5
V
Secondary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
Secondary Undervoltage Lockout
Threshold
VSEC_UVLO- Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
14
15
16
V
Secondary Undervoltage Lockout
Response Time
tSEC_UVLO
100
µs
Primary Undervoltage Lockout
Threshold
Applies only to reversilbe products in forward and in
VPRI_UVLO-_R
reverse direction; IPRI_DC ≤ 20% while VPRI_UVLO-_R
< VPRI_DC < VPRI_MIN
110
120
130
V
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+_R
Applies only to reversilbe products in forward and in
reverse direction
120
130
150
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST_R
Applies only to reversilbe products in forward and in
reverse direction
10
V
Primary Output Overcurrent Trip
Threshold
IPRI_OUT_OCP Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
3.5
4
6
A
Primary Output Overcurrent
Response Time Constant
tPRI_OUT_OCP Effective internal RC filter
3.6
ms
Primary Short Circuit Protection Trip
Threshold
IPRI_SCP
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
5.6
A
Primary Short Circuit Protection
Response Time
tPRI_SCP
1
µs
BCM® Bus Converter
Page 10 of 30
Rev 1.1
01/2017
vicorpower.com
800 927.9474