English
Language : 

BCM6123XD1E5126YZZ Datasheet, PDF (14/30 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM6123xD1E5126yzz
PMBus™ Control Signal Characteristics
Specifications apply over all line, load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
UART SER-IN / SER-OUT Pins
• Universal Asynchronous Receiver/Transmitter (UART) pins.
• The BCM communication version is not intended to be used without a Digital Supervisor.
• Isolated I2C communication and telemetry is available when using Vicor Digital Isolator and Vicor Digital Supervisor. Please see specific product data sheet
for more details.
• UART SER-IN pin is internally pulled high using a 1.5kΩ to 3.3V.
SIGNAL TYPE
STATE
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN TYP MAX UNIT
GENERAL I/O
DIGITAL
INPUT
Regular
Operation
Baud Rate
SER-IN Pin
SER-IN Input Voltage Range
SER-IN rise time
SER-IN fall time
SER-IN RPULLUP
SER-IN External Capacitance
SER-OUT Pin
BRUART Rate
VSER-IN_IH
VSER-IN_IL
tSER-IN_RISE 10% to 90%
tSER-IN_FALL 10% to 90%
RSER-IN_PLP Pull up to 3.3V
CSER-IN_EXT
750
Kbit/s
2.3
V
1
V
400
ns
25
ns
1.5
kΩ
400 pF
DIGITAL
OUTPUT
SER-OUT Output Voltage
Range
VSER-OUT_OH 0mA ≥ IOH ≥ -4mA
VSER-OUT_OL 0mA ≤ IOL ≤ 4mA
SER-OUT rise time
SER-OUT fall time
SER-OUT source current
SER-OUT output impedance
tSER-OUT_RISE 10% to 90%
tSER-OUT_FALL 10% to 90%
ISER-OUT
VSER-OUT = 2.8V
ZSER-OUT
2.8
V
0.5
V
55
ns
45
ns
6
mA
120
Ω
Enable / Disable Control
• The EN pin is a standard analog I/O configured as an input to an internal µC.
• It is internally pulled high to 3.3V.
• When held low the BCM internal bias will be disabled and the powertrain will be inactive.
• In an array of BCMs, EN pins should be interconnected to synchronize startup.
• Enable / disable command will have no effect if the EN pin is disabled.
SIGNAL TYPE
ANALOG
INPUT
STATE
Startup
Regular
Operation
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN
EN to Powertrain active time
EN Voltage Threshold
tEN_START
VENABLE
VPRI_DC > VPRI_UVLO+,
EN held low both conditions satisfied
for t > tPRI_UVLO+_DELAY­
2.3
EN Resistance (Internal)
REN_INT Internal pull up resistor
EN Disable Threshold
VEN_DISABLE_TH
TYP MAX UNIT
250
µs
V
1.5
kΩ
1
V
BCM® Bus Converter
Page 14 of 30
Rev 1.1
01/2017
vicorpower.com
800 927.9474