Evaluation Board Bias Procedure
Following bias procedure is recommended to ensure proper functionality of AP561 in a laboratory environment. The
sequencing is not required in the final system application.
Bias.
VCC
VPD
Voltage (V)
+12
+5
Turn-on Sequence:
1. Attach input and output loads onto the evaluation board.
2. Turn on power supply VCC = +12V.
3. Turn on power supply VPD = +5V.
4. Turn on RF power.
Turn-off Sequence:
1. Turn off RF power.
2. Turn off power supply VPD = +5V.
3. Turn off power supply VCC = +12V.