Timing Requirements (continued)
TA = –40°C to +105°C
I2C BUS
MIN
tSP
Pulse width of spikes that must be
suppressed by the input filter (7)
STANDARD MODE
FAST MODE
FAST MODE PLUS
RESET
STANDARD MODE
10
tW
Reset pulse width
FAST MODE
10
FAST MODE PLUS
10
STANDARD MODE
0
tREC
Reset recovery time
FAST MODE
0
FAST MODE PLUS
0
tRESET
Time to reset (8) (9)
STANDARD MODE
400
FAST MODE
400
FAST MODE PLUS
400
(7) Input filters on the SDA and SCL inputs suppress noise spikes less than 50 ns.
(8) Resetting the device while actively communicating on the bus may cause glitches or errant Stop conditions.
(9) Upon reset, the full delay will be the sum of tRESET and the RC time constant of the SDA bus.
www.ti.com
MAX
50