English
Language : 

TCA9554_15 Datasheet, PDF (7/38 Pages) Texas Instruments – TCA9554 Low Voltage 8-Bit I2C and SMBus Low-Power I/O Expander With Interrupt Output and Configuration Registers
www.ti.com
TCA9554
SCPS233D – MARCH 2012 – REVISED AUGUST 2015
6.6 I2C Interface Timing Requirements
over operating free-air temperature range (unless otherwise noted) (see Figure 10)
fscl
tsch
tscl
tsp
tsds
tsdh
ticr
ticf
tocf
tbuf
tsts
tsth
tsps
tvd(data)
tvd(ack)
Cb
I2C clock frequency
I2C clock high time
I2C clock low time
I2C spike time
I2C serial-data setup time
I2C serial-data hold time
I2C input rise time
I2C input fall time
I2C output fall time
10-pF to 400-pF bus
I2C bus free time between Stop and Start
I2C Start or repeated Start condition setup
I2C Start or repeated Start condition hold
I2C Stop condition setup
Valid data time
SCL low to SDA output valid
Valid data time of ACK condition
ACK signal from SCL low to
SDA (out) low
I2C bus capacitive load
STANDARD MODE
I2C BUS
MIN
MAX
0
100
4
4.7
50
250
0
1000
300
300
4.7
4.7
4
4
3.45
3.45
400
FAST MODE
I2C BUS
MIN
0
0.6
1.3
100
0
20
20 × (VDD / 5.5 V)
20 × (VDD / 5.5 V)
1.3
0.6
0.6
0.6
MAX
400
50
300
300
300
0.9
UNIT
kHz
µs
µs
ns
ns
ns
ns
ns
ns
µs
µs
µs
µs
µs
0.9 µs
400 pF
6.7 Switching Characteristics
over operating free-air temperature range (unless otherwise noted) (see Figure 11 and Figure 12)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
STANDARD MODE
I2C BUS
MIN
MAX
tiv Interrupt valid time
tir Interrupt reset delay time
tpv Output data valid
tps Input data setup time
tph Input data hold time
P port
SCL
SCL
P port
P port
INT
INT
P7–P0
SCL
SCL
4
4
350
100
1
FAST MODE
I2C BUS
MIN MAX
4
4
350
100
1
UNIT
µs
µs
ns
ns
µs
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: TCA9554
Submit Documentation Feedback
7