Electrical Characteristics (continued)
4.5 V ≤ VVCC ≤ 24 V, 0°C ≤ TJ ≤ 125°C, typical values are at TA = 25°C, with respect to GND (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
IREGN_LIM
REGN current limit
VREGN = 0V, VVCC > UVLO charge enabled and not in
TSHUT
VREGN = 0V, VVCC > UVLO charge disabled or in
TSHUT
50
75
7
14
CREGN
REGN output capacitor required for
stability
ILOAD = 100µA to 50mA
1
INPUT UNDERVOLTAGE LOCKOUT COMPARATOR (UVLO)
UVLO
Under voltage rising threshold
Under voltage hysteresis, falling
FAST DPM COMPARATOR (FAST_DPM)
VVCC rising
VVCC falling
3.5 3.75
4
340
VFAST_DPM
Fast DPM comparator stop charging rising threshold with respect to input current limit, voltage
across input sense resistor rising edge
103% 107% 111%
QUIESCENT CURRENT
IBAT_BATFET_OFF
Battery BATFET OFF STATE Current,
BATFET off,
ISRP + ISRN + IPHASE + IACP + IACN
IBAT_BATFET_ON
Battery BATFET ON STATE Current,
BATFET on,
ISRP + ISRN + IPHASE + IVCC + IACP + IACN
ISTANDBY
Standby quiescent current, IVCC + IACP +
IACN
IAC_NOSW
Adapter bias current during charge,
IVCC + IACP + IACN
IAC_SW
Adapter bias current during charge,
IVCC + IACP + IACN
ACOK COMPARATOR
VVBAT = 16.8V, VCC disconnect from battery, BATFET
charge pump off, BATFET turns off, TJ = 0 to 85°C
VVBAT = 16.8V, VCC connect from battery, BATFET
charge pump on, BATFET turns on, TJ = 0 to 85°C
VVCC > UVLO, VACDET > 0.6V, charge disabled,
TJ = 0 to 85°C
VVCC > UVLO, 2.4V < VACDET < 3.15V,
charge enabled, no switching, TJ = 0 to 85°C
VVCC > UVLO, 2.4V < VACDET < 3.15V,
charge enabled, switching, MOSFET Sis412DN
5
25
0.65
0.8
1.5
3
10
VACOK_RISE
VACOK_FALL_HYS
VACOK_RISE_DEG
ACOK rising threshold
ACOK falling hysteresis
ACOK rising deglitch (Specified by design)
VVCC > UVLO, VACDET rising
VVCC> UVLO, VACDET falling
VVCC> UVLO, VACDET rising above 2.4V,
First time OR ChargeOption() bit [15] = 0
VVCC> UVLO, VACDET rising above 2.4V,
(NOT First time) AND ChargeOption() bit [15] = 1
(Default)
2.376
35
100
2.4 2.424
55
75
150
200
0.9
1.3
1.7
VWAKEUP_RISE
WAKEUP detect rising threshold
VWAKEUP_FALL
WAKEUP detect falling threshold
VCC to SRN COMPARATOR (VCC_SRN)
VVCC> UVLO, VACDET rising
VVCC> UVLO, VACDET falling
0.57
0.8
0.3 0.51
VVCC-SRN_FALL
VCC-SRN falling threshold
VVCC-SRN _RHYS
VCC-SRN rising hysteresis
ACN to SRN COMPARATOR (ACN_SRN)
VVCC falling towards VSRN
VVCC rising above VSRN
70
125
200
100
150
200
VACN-SRN_FALL
ACN to BAT falling threshold
VACN-SRN_RHYS
ACN to BAT rising hysteresis
HIGH SIDE IFAULT COMPARATOR (IFAULT_HI)(1)
VACN falling towards VSRN
VACN rising above VSRN
120
200
280
40
80
120
VIFAULT_HI_RISE
ACP to PHASE rising threshold
LOW SIDE IFAULT COMPARATOR (IFAULT_LOW)(1)
ChargeOption() bit [8] = 1 (Default)
ChargeOption() bit [8] = 0 Disable function
450
750 1200
VIFAULT_LOW_RISE PHASE to GND rising threshold
ChargeOption() bit [7] = 0 (Default)
ChargeOption() bit [7] = 1
70
135
220
140
230
340
INPUT OVER-VOLTAGE COMPARATOR (ACOV)
VACOV
ACDET over voltage rising threshold
VACOV_HYS
ACDET over voltage falling hysteresis
INPUT OVER-CURRENT COMPARATOR (ACOC)(1)
VACDET rising
VACDET falling
3.05 3.15 3.25
50
75
100
VACOC
Adapter over current rising threshold with
respect to input current limit, voltage
across input sense resistor rising edge
ChargeOption() bit [1] = 1 (Default)
ChargeOption() bit [1] = 0 Disable function
300% 333% 366%
UNIT
mA
mA
µF
V
mV
µA
µA
mA
mA
mA
V
mV
ms
s
V
V
mV
mV
mV
mV
mV
mV
V
mV
(1) User can adjust threshold via SMBus ChargeOption() REG0x12.