English
Language : 

BQ40Z60_16 Datasheet, PDF (6/47 Pages) Texas Instruments – Programmable Battery Management Unit
bq40z60
SLUSAW3C – DECEMBER 2014 – REVISED JULY 2015
www.ti.com
Recommended Operating Conditions (continued)
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
MIN
NOM
MAX UNIT
ACP, SMBC, SMBD, ALERT, SYSPRES
26
TSx
SRP, SRN
–0 .2
VREG
0.2
HSRP, HSRN
–0 .5
0.5
PH
VIN
Input voltage range
VFB
–2
VACP
V
0
14
VC4
VC3
VC2
VC1
CHG, DSG, AFEFUSE
VO
Output voltage
range
HIDRV
LODRV
VVC3
VVC2
VVC1
VVSS
0
VVC3 + 5
VVC2 + 5
VVC1 + 5
VVSS + 5
26 V
35 V
6.5 V
CPBI
External PBI
capacitor
2.2
µF
TOPR
Operating
temperature
–40
85 °C
8.4 Thermal Information
THERMAL METRIC(1)
bq40z60
RHB (VQFN)
UNIT
32 PINS
RθJA, High K
RθJC(top)
RθJB
ψJT
ψJB
RθJCbot
Junction-to-ambient thermal resistance
Junction-to-case(top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case(bottom) thermal resistance
36
°C/W
31.5
°C/W
8
°C/W
0.5
°C/W
7.9
°C/W
2.2
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
8.5 Supply Voltage
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
Operation with charger enabled
VCC
Device Operating Range
Operation with charger disabled
4.0
25
V
2.5
25
VCC-UV Undervoltage lock out VCC falling
2.2
2.45 V
6
Submit Documentation Feedback
Product Folder Links: bq40z60