English
Language : 

BQ40Z60_16 Datasheet, PDF (10/47 Pages) Texas Instruments – Programmable Battery Management Unit
bq40z60
SLUSAW3C – DECEMBER 2014 – REVISED JULY 2015
ADC(1) (continued)
Over-operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
Offset error drift
Gain error
Gain error drift
Effective input resistance
16-bit, Post-calibration, VFS = VREF1
16-bit, –0.1 V to 0.8 × VFS
16-bit, –0.1 V to 0.8 × VFS
www.ti.com
MIN
TYP
0.6
±0.2%
8
MAX
3
±0.8%
150
UNIT
µV/°C
FSR
PPM/°C
MΩ
8.16 ADC Digital Filter
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
ADCTL[SPEED1, SPEED0] = 0, 0
31.25
Conversion time
ADCTL[SPEED1, SPEED0] = 0, 1
ADCTL[SPEED1, SPEED0] = 1, 0
15.63
ms
7.81
ADCTL[SPEED1, SPEED0] = 1, 1
1.95
Resolution
No missing codes, ADCTL[SPEED1, SPEED0] = 0, 0
16
Bits
With sign, ADCTL[SPEED1, SPEED0] = 0, 0
14
15
With sign, ADCTL[SPEED1, SPEED0] = 0, 1
13
14
Effective resolution
Bits
With sign, ADCTL[SPEED1, SPEED0] = 1, 0
11
12
With sign, ADCTL[SPEED1, SPEED0] = 1, 1
9
10
8.17 ADC Multiplexer
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
VC1–VSS, VC2–VC1, VC3–VC2, VC4–VC3
0.1980
0.2000
0.2020
K
Scaling factor
VC4–VSS, ACP–VSS
VREF2
HSRN–VSS
0.049
0.490
0.049
0.050
0.500
0.050
0.051
—
0.510
0.051
VC4–VSS, ACP–VSS
–0.2
20
VIN
Input voltage range
TSx
–0.2
TSx
–0.2
ILKG
Input leakage current
VC1, VC2, VC3, VC4, cell balancing off, cell
detach detection off, ADC multiplexer off
0.8 × VREF1
V
0.8 × VREG
1 µA
8.18 Cell Balancing Support
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
MAX UNIT
RCB
Internal cell balance
resistance
RDS(ON) for internal FET switch at 2 V < VDS < 4 V
200 Ω
8.19 Cell Detach Detection
Typical values stated where TA = 25°C and VCC = 10.8 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
MAX UNIT
ICD
Internal cell detach
check current
VCx > VSS + 0.8 V
30
50
70 µA
10