7.6 Insulation Specifications
PARAMETER
TEST CONDITIONS
VALUE
UNIT
GENERAL
CLR
Minimum air gap (clearance)(1)
Shortest pin-to-pin distance through air
≥8
mm
CPG
Minimum external tracking (creepage)(1)
Shortest pin-to-pin distance across the package
surface
≥8
mm
DTI
Distance through insulation
Minimum internal gap (internal clearance) of the
double insulation (2 × 0.0135 mm)
0.027
mm
CTI
Comparative tracking index
DIN EN 60112 (VDE 0303-11); IEC 60112
≥ 600
V
Material group
According to IEC 60664-1
I
Rated mains voltage ≤ 300 VRMS
I-IV
Overvoltage category per IEC 60664-1 Rated mains voltage ≤ 600 VRMS
I-III
Rated mains voltage ≤ 1000 VRMS
I-II
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12(2)
VIORM
Maximum repetitive peak isolation
voltage
At ac voltage (bipolar or unipolar)
1414
VPK
VIOWM
VIOTM
Maximum-rated isolation working
voltage
Maximum transient isolation voltage
At ac voltage (sine wave)
At dc voltage
VTEST = VIOTM, t = 60 s (qualification test)
VTEST = 1.2 x VIOTM, t = 1 s (100% production
test)
1000
1500
7000
8400
VRMS
VDC
VPK
Test method per IEC 60065, 1.2/50-μs
VIOSM
Maximum surge isolation voltage(3)
waveform, VTEST = 1.6 x VIOSM = 10000 VPK
6250
VPK
(qualification)
Method a, after input/output safety test subgroup
2 / 3, Vini = VIOTM, tini = 60 s, Vpd(m) = 1.2 x VIORM
≤5
pC
= 1697 VPK, tm = 10 s
qpd
Apparent charge(4)
Method a, after environmental tests subgroup 1,
Vini = VIOTM, tini = 60 s, Vpd(m) = 1.6 x VIORM =
≤5
pC
2263 VPK, tm = 10 s
Method b1, at routine test (100% production) and
preconditioning (type test), Vini = VIOTM, tini = 1 s,
≤5
pC
Vpd(m) = 1.875 x VIORM = 2652 VPK, tm = 1 s
CIO
Barrier capacitance, input to output(5) VIO = 0.5 VPP at 1 MHz
1.2
pF
RIO
Insulation resistance, input to output(5) VIO = 500 V at TS = 150°C
> 109
Ω
Pollution degree
2
Climatic category
40/125/21
UL1577
VISO
Withstand isolation voltage
VTEST = VISO = 5000 VRMS or 7000 VDC, t = 60 s
(qualification test), VTEST = 1.2 x VISO = 6000
VRMS, t = 1 s (100% production test)
5000
VRMS
(1) Apply creepage and clearance requirements according to the specific equipment isolation standards of an application. Care must be
taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on the printed
circuit board (PCB) do not reduce this distance. Creepage and clearance on a PCB become equal in certain cases. Techniques such as
inserting grooves or ribs on the PCB are used to help increase these specifications.
(2) This coupler is suitable for safe electrical insulation only within the safety ratings. Compliance with the safety ratings shall be ensured by
means of suitable protective circuits.
(3) Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier.
(4) Apparent charge is electrical discharge caused by a partial discharge (pd).
(5) All pins on each side of the barrier are tied together, creating a two-pin device.
6
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: AMC1304L05-Q1 AMC1304L25-Q1 AMC1304M05-Q1 AMC1304M25-Q1