Typical Applications (continued)
9.2.1.3 Application Curve
In motor control applications, a very fast response time for overcurrent detection is required. The time for fully
settling the filter in case of a step-signal at the input of the modulator depends on its order; that is, a sinc3 filter
requires three data updates for full settling (with fDATA = fCLK / OSR). Therefore, for overcurrent protection, filter
types other than sinc3 can be a better choice; an alternative is the sinc2 filter. Figure 55 compares the settling
times of different filter orders.
The delay time of the sinc filter with a continuous signal is half of its settling time.
16
14
12
10
8
6
4
sinc1
2
sinc2
sinc3
0
0 2 4 6 8 10 12 14 16 18 20
settling time (µs)
D054
Figure 55. Measured Effective Number of Bits versus Settling Time
Copyright © 2017, Texas Instruments Incorporated
Submit Documentation Feedback
27
Product Folder Links: AMC1304L05-Q1 AMC1304L25-Q1 AMC1304M05-Q1 AMC1304M25-Q1