8.7.37 Address: 0x24
Figure 81. 0x24
7
R/W-0
6
R/W-1
5
R/W-1
4
3
RATED_VOLTAGE_CLAMP[7:0]
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 38. Address: 0x24
2
R/W-1
1
R/W-0
0
R/W-0
BIT FIELD
TYPE DEFAULT DESCRIPTION
7-0 RATED_VOLTAGE_CLAMP[ R/W
7:0]
100 This parameter is to set a clamp for the steady state voltage provided by the driver. This clamp
is enforced after the overdrive section of the waveform. Note that if the OD_CLAMP is lower
than this parameter, the lower clamp will be applied. The same is true if the
BAT_LIFE_EXT_LVLx is triggered.
8.7.38 Address: 0x25
Figure 82. 0x25
7
6
5
4
3
OD_CLAMP_LVL1[7:0]
R/W-1
R/W-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
2
R/W-0
1
R/W-0
0
R/W-0
BIT FIELD
7-0 OD_CLAMP_LVL1[7:0]
Table 39. Address: 0x25
TYPE
R/W
DEFAULT DESCRIPTION
128 This parameter overwrites OD_CLAMP once VBAT is below BAT_LIFE_EXT_LVL1 value. This
parameter will be ignored during autocal and diagnostics.
8.7.39 Address: 0x26
Figure 83. 0x26
7
6
5
4
3
2
1
0
OD_CLAMP_LVL2[7:0]
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
BIT FIELD
7-0 OD_CLAMP_LVL2[7:0]
Table 40. Address: 0x26
TYPE
R/W
DEFAULT DESCRIPTION
0
This parameter overwrites OD_CLAMP and OD_CLAMP_LVL1 once VBAT is below
BAT_LIFE_EXT_LVL2 value. This parameter will be ignored during autocal and diagnostics.
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: DRV2624
Submit Documentation Feedback
55