Programming/Reprogramming the eZ430-Chronos Watch: Disassembly and Assembly of the Housing
www.ti.com
4. Remove the battery before connecting the module to the emulator. Place the screwdriver tip between
the battery and the battery holder (small metal tab) and push the tab away from battery (see Figure 4-
2). Detailed instructions are shown in the eZ430-Chronos Disassembly/Assembly video on
www.ti.com/chronoswiki.
Figure 4-2. Removing Watch Battery
CAUTION
Always remove the battery from the watch before connecting the watch to an
emulator, to prevent the battery from being charged.
WARNING
Properly dispose of the battery. Keep the battery out of the reach
of children. If the battery is swallowed, contact a physician
immediately.