TABLE 13. ANODE CONNECT REGISTER (ADDRESS 0x25)
Bits [7]
Not Used
Bit 6
LVLED5
Anode
Connect
0 = LVLED5
LED anode is
not connected
to CPOUT
1 = LVLED5
LED anode is
connected to
CPOUT
(Default)
Bit 5
LVLED4 Anode
Connec
Bit 4
LVLED3
Anode
Connect
0 = LVLED4 0 = LVLED3
LED anode is LED anode is
not connected to not connected
CPOUT
to CPOUT
1 = LVLED4
LED anode is
connected to
CPOUT
(Default)
1 = LVLED3
LED anode is
connected to
CPOUT
(Default)
Bit 3
LVLED2
Anode
Connect
0 = LVLED2
LED anode is
not connected
to CPOUT
1 = LVLED2
LED anode is
connected to
CPOUT
(Default)
Bit 2
LVLED1 Anode
Connect
Bit 1
HVLED2
Anode
Connect
0 = LVLED1 0 = HVLED2
LED anode is LED string
not connected to anode is not
CPOUT
connected to
COUT
1 = LVLED1 1 = HVLED2
LED anode is LED string
connected to anode is
CPOUT
connected to
(Default)
COUT
(Default)
Bit 0
HVLED1
Anode
Connect
0 = HVLED1
LED string
anode is not
connected to
COUT
1 = HVLED1
LED string
anode is
connected to
COUT
(Default)
Bits [7:3]
Not Used
N/A
TABLE 14. CHARGE PUMP CONTROL REGISTER (ADDRESS 0x26)
Bits [2:1]
Gain Select
0X = Automatic gain select (Default)
10 = Gain set at 1x
11 = Gain set at 2x
Bit 0
Charge Pump Disable
0 = Charge pump enabled (Default)
1 = Charge pump disabled; charge pump is high
impedance from IN to CPOUT.
Bits [7:6]
Not Used
TABLE 15. CONTROL BANK ENABLE REGISTER (ADDRESS 0x27)
Bit 5
Control F
Enable
Bit 4
Control E
Enable
Bit 3
Control D
Enable
Bit 2
Control C
Enable
Bit 1
Control B
Enable
Bit 0
Control A
Enable
0 = Control Bank 0 = Control Bank 0 = Control Bank 0 = Control Bank 0 = Control Bank 0 = Control
F is disabled E is disabled
D is disabled
C is disabled B is disabled Bank A is
(Default)
(Default)
(Default)
(Default)
(Default)
disabled
(Default)
1 = Control Bank 1 = Control Bank 1 = Control Bank 1 = Control Bank 1 = Control Bank 1 = Control
F is enabled E is enabled
D is enabled
C is enabled
B is enabled
Bank A is
enabled
TABLE 16. PATTERN GENERATOR ENABLE/ALS SCALING CONTROL (ADDRESS 0X28)
Bit 7
Pattern 4
ALS Scaling
Enable
Bit 6
Pattern 4
Enable
0 = Pattern 4 0 = Pattern 4
Scaling
Disabled
Disabled
(Default)
(Default)
1 = Pattern 4 1 = Pattern 4
Scaling
Enabled
Enabled
Bit 5
Pattern 3
ALS Scaling
Enable
0 = Pattern 3
Scaling
Disabled
(Default)
1 = Pattern 3
Scaling
Enabled
Bit 4
Pattern 3
Enable
0 = Pattern 3
Disabled
(Default)
1 = Pattern 3
Enabled
Bit 3
Pattern 2
ALS Scaling
Enable
0 = Pattern 2
Scaling
Disabled
(Default)
1 = Pattern 2
Scaling
Enabled
Bit 2
Pattern 2
Enable
0 = Pattern 2
Disabled
(Default)
1 = Pattern 2
Enabled
Bit 1
Pattern 1
ALS Scaling
Enable
Bit 0
Pattern 1
Enable
0 = Pattern 1 0 = Pattern 1
Scaling
Disabled
Disabled
(Default)
(Default)
1 = Pattern 1 1 = Pattern 1
Scaling
Enabled
Enabled
Note: If a low-voltage control bank is set to receive its brightness information from either ALSM2 or ALSM3, and then a pattern
generator is enabled for that Control Bank, the Control Bank will ignore the ALSM2 or ALSM3 zone target information. This prevents
conflicts from ALSM2/ALSM3 zone targets and ALS controlled pattern currents.