SWRS206A – MARCH 2017 – REVISED JUNE 2017
5.4 Current Consumption (CC3220MODS)
TA = 25°C, VBAT = 3.6 V
PARAMETER
TEST CONDITIONS(1) (2)
MIN TYP MAX UNIT
TX power level = 0
272
1 DSSS
TX power level = 4
190
TX
MCU ACTIVE
NWP ACTIVE
6 OFDM
54 OFDM
TX power level = 0
TX power level = 4
TX power level = 0
TX power level = 4
248
182
223
mA
160
RX (3)
NWP idle connected(4)
1 DSSS
54 OFDM
59
59
15.3
TX power level = 0
269
1 DSSS
TX power level = 4
187
MCU SLEEP
TX
NWP ACTIVE
6 OFDM
54 OFDM
TX power level = 0
TX power level = 4
TX power level = 0
TX power level = 4
245
179
220
mA
157
RX (3)
NWP idle connected(4)
1 DSSS
54 OFDM
56
56
12.2
TX power level = 0
266
1 DSSS
TX power level = 4
184
TX
NWP active
MCU LPDS
6 OFDM
54 OFDM
TX power level = 0
TX power level = 4
TX power level = 0
TX power level = 4
242
176
mA
217
154
RX (3)
NWP LPDS(5)
NWP idle connected(4)
1 DSSS
54 OFDM
53
53
135
µA
710
µA
MCU hibernate
MCU shutdown
NWP hibernate
NWP shutdown
5
µA
1
Peak calibration current (6)
VBAT = 3.6 V
VBAT = 3.3 V
VBAT= 2.3 V
420
450
mA
620
(1) TX power level = 0 implies maximum power (see Figure 5-1, Figure 5-2, and Figure 5-3). TX power level = 4 implies output power
backed off approximately 4 dB.
(2) The CC3220MODx system is a constant power-source system. The active current numbers scale based on the VBAT voltage supplied.
(3) The RX current is measured with a 1-Mbps throughput rate.
(4) DTIM = 1
(5) The LPDS number of reported is with retention of 256KB of MCU SRAM. The CC3220MODx module can be configured to retain 0KB,
64KB, 128KB, 192KB, or 256KB of SRAM in LPDS. Each 64-KB block of MCU retained SRAM increases LPDS current by 4 μA.
(6) The complete calibration can take up to 17 mJ of energy from the battery over a time of 24 ms. In default mode, calibration is performed
sparingly, and typically occurs when re-enabling the NWP and when the temperature has changed by more than 20°C. There are two
additional calibration modes that may be used to reduced or completely eliminate the calibration event. For further details, see CC3x20