DS92LV2421SQX-NOPB Datasheet, PDF (27/50 Pages) Texas Instruments – DS92LV2421/DS92LV2422 10 to 75 MHz, 24-bit Channel Link II Serializer and Deserializer
DS92LV2421, DS92LV2422
www.ti.com
SNLS321B – MAY 2010 – REVISED APRIL 2013
Table 7. SSCG Configuration (LF_MODE = H) — Des Output
SSC3
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
SSC[3:0] Inputs
LH_MODE = H (10 - 20 MHz)
SSC2
SSC1
L
L
L
L
L
H
L
H
H
L
H
L
H
H
H
H
L
L
L
L
L
H
L
H
H
L
H
L
H
H
H
H
SSC0
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
Result
fdev (%)
NA
±0.5
±1.0
±1.5
±2.0
±0.5
±1.0
±1.5
±2.0
±0.5
±1.0
±1.5
±2.0
±0.5
±1.0
±1.5
fmod (kHz)
Disable
CLK/620
CLK/370
CLK/258
CLK/192
1.8V or 3.3V VDDIO Operation
The Des parallel bus and Serial Bus Interface can operate with 1.8 V or 3.3 V levels (VDDIO) for target (Display)
compatibility. The 1.8 V levels will offer a lower noise (EMI) and also a system power savings.
Power Saving Features
Des — PowerDown Feature (PDB)
The Des has a PDB input pin to ENABLE or POWER DOWN the device. This pin can be controlled by the
system to save power, disabling the Des when the display is not needed. An auto detect mode is also available.
In this mode, the PDB pin is tied High and the Des will enter POWER DOWN when the serial stream stops.
When the serial stream starts up again, the Des will lock to the input stream and assert the LOCK pin and output
valid data. In POWER DOWN mode, the Data and CLKOUT output states are determined by the OSS_SEL
status. Note – in POWER DOWN, the optional Serial Bus Control Registers are RESET.
Des — Stop Stream SLEEP Feature
The Des will enter a low power SLEEP state when the input serial stream is stopped. A STOP condition is
detected when the embedded clock bits are not present. When the serial stream starts again, the Des will then
lock to the incoming signal and recover the data. Note – in STOP STREAM SLEEP, the optional Serial Bus
Control Registers values are RETAINED.
Des — CLOCK-DATA RECOVERY STATUS FLAG (LOCK) and OUTPUT STATE SELECT (OSS_SEL)
When PDB is driven HIGH, the CDR PLL begins locking to the serial input and LOCK goes from TRI-STATE to
LOW (depending on the value of the OSS_SEL setting). After the DS92LV2422 completes its lock sequence to
the input serial data, the LOCK output is driven HIGH, indicating valid data and clock recovered from the serial
input is available on the parallel bus and clock outputs. The CLKOUT output is held at its current state at the
change from OSC_CLK (if this is enabled via OSC_SEL) to the recovered clock (or vice versa).
If there is a loss of clock from the input serial stream, LOCK is driven Low and the state of the outputs are based
on the OSS_SEL setting (STRAP PIN configuration or register).
Copyright © 2010–2013, Texas Instruments Incorporated
Submit Documentation Feedback
27
Product Folder Links: DS92LV2421 DS92LV2422