English
Language : 

BQ28Z560-R1 Datasheet, PDF (21/60 Pages) Texas Instruments – Single Cell Li-Ion Battery Gas Gauge and Protection
bq28z560-R1
www.ti.com
CNTL FUNCTION
FW_VERSION
HW_VERSION
Reserved
RESET_DATA
Reserved
PREV_MACWRITE
CHEM_ID
BOARD_OFFSET
CC_OFFSET
CC_OFFSET_SAVE
DF_VERSION
SET_FULLSLEEP
SET_HIBERNATE
CLEAR_HIBERNATE
SET_SHUTDOWN
CLEAR_SHUTDOWN
SET_HDQINTEN
CLEAR_HDQINTEN
STATIC_CHEM_CHKSUM
HOST_DISCONNECT
HOST_CONNECT
SEALED
IT_ENABLE
CAL_ENABLE
RESET
EXIT_CAL
ENTER_CAL
OFFSET_CAL
SLUSBD3 – APRIL 2013
Table 4. Control() Subcommands (continued)
CNTL DATA
0x0002
0x0003
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009
0x000A
0x000B
0x000C
0x0010
0x0011
0x0012
0x0013
0x0014
0x0015
0x0016
0x0017
0x0018
0x0019
0x0020
0x0021
0x002d
0x0041
0x0080
0x0081
0x0082
SEALED
ACCESS
Yes
Yes
No
No
No
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
DESCRIPTION
Reports the firmware version on the device type
Reports the hardware version of the device type
Not to be used
Returns reset data
Not to be used
Returns previous MAC command code
Reports the chemical identifier of the Impedance Track configuration
Forces the device to measure and store the board offset
Forces the device to measure and internal CC offset
Forces the device to store the internal CC offset
Reports the data flash version on the device
Set the [FULLSLEEP] bit in Control Status register to 1
Forces CONTROL_STATUS [HIBERNATE] to 1
Forces CONTROL_STATUS [HIBERNATE] to 0
Forces CONTROL_STATUS [SHUTDOWN] to 1. SET_SHUTDOWN
enables the system to enter into SHUTDOWN mode.
Forces CONTROL_STATUS [SHUTDOWN] to 0
Forces CONTROL_STATUS [HDQIntEn] to 1
Forces CONTROL_STATUS [HDQIntEn] to 0
Calculates chemistry checksum
Forces the DOUT pin low to disable discharge
Clears DSGFETOFF, allowing DOUT to go high if no other conditions force
it low
Places the bq28z560-R1 in SEALED ACCESS mode
Enables the Impedance Track algorithm
Toggle bq28z560-R1 CALIBRATION mode
Forces a full reset of the bq28z560-R1
Exit bq28z560-R1 CALIBRATION mode
Enter bq28z560-R1 CALIBRATION mode
Reports internal CC offset in CALIBRATION mode
CONTROL_STATUS: 0x0000
Instructs the gas gauge to return status information to Control addresses 0x00/0x01. The status word includes
the following information.
High Byte
Low Byte
Bit 7
DSGFETOFF
SHUTDOWN
Table 5. CONTROL_STATUS Flags
Bit 6
FAS
HIBERNATE
Bit 5
SS
FULLSLEEP
Bit 4
CALMODE
SLEEP
Bit 3
CCA
LDMD
Bit 2
BCA
RUP_DIS
Bit 1
CSV
VOK
Bit 0
HDQIntEn
QEN
DSGFETOFF = State bit indicating the DISCHARGE FET has been disabled by HOST (HOST DISCONNECT).
FAS = Status bit indicating the bq28z560-R1 is in FULL ACCESS SEALED state. Active when set.
SS = Status bit indicating the bq28z560-R1 is in the SEALED state. Active when set.
CALMODE = Status bit indicating the calibration function is active. True when set. Default is 0.
CCA =
Status bit indicating the bq28z560-R1 coulomb counter Calibration routine is active. The CCA routine takes place
approximately 1 minute after the initialization and periodically as gauging conditions change. Active when set.
BCA = Status bit indicating the bq28z560-R1 Board Calibration routine is active. Active when set.
CSV = Status bit indicating a valid data flash checksum has been generated. Active when set.
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: bq28z560-R1
Submit Documentation Feedback
21