DATA COMMANDS
www.ti.com
STANDARD DATA COMMANDS
The bq28z560-R1 uses a series of 2-byte standard commands to enable system reading and writing of battery
information. Each standard command has an associated command-code pair, as indicated in Table 3. Each
protocol has specific means to access the data at each Command Code. DataRAM is updated and read by the
gauge only once per second. Standard commands are accessible in normal operation mode.
Control()
AtRate()
AtRateTimeToEmpty()
Temperature()
Voltage()
Flags()
NominalAvailableCapacity()
FullAvailableCapacity()
RemainingCapacity()
FullChargeCapacity()
AverageCurrent()
TimeToEmpty()
TimeToFull()
StandbyCurrent()
StandbyTimeToEmpty()
MaxLoadCurrent()
MaxLoadTimeToEmpty()
AvailableEnergy()
AveragePower()
TTEatConstantPower()
Internal_Temp()
CycleCount()
StateOfCharge()
StateOfHealth()
PassedCharge()
DOD0()
SelfDischargeCurrent()
NAME
Table 3. Standard Commands
CNTL
AR
ARTTE
TEMP
VOLT
FLAGS
NAC
FAC
RM
FCC
AI
TTE
TTF
SI
STTE
MLI
MLTTE
AE
AP
TTECP
INTTEMP
CC
SOC
SOH
PCHG
DOD0
SDSG
COMMAND CODE
0x00 / 0x01
0x02 / 0x03
0x04 / 0x05
0x06 / 0x07
0x08 / 0x09
0x0a / 0x0b
0x0c / 0x0d
0x0e / 0x0f
0x10 / 0x11
0x12 / 0x13
0x14 / 0x15
0x16 / 0x17
0x18 / 0x19
0x1a / 0x1b
0x1c / 0x1d
0x1e / 0x1f
0x20 / 0x21
0x22 / 0x23
0x24 / 0x25
0x26 / 0x27
0x28 / 0x29
0x2a / 0x2b
0x2c / 0x2d
0x2e / 0x2f
0x34 / 0x35
0x36 / 0x37
0x38 / 0x39
UNITS
N/A
mA
Minutes
0.1K
mV
N/A
mAh
mAh
mAh
mAh
mA
Minutes
Minutes
mA
Minutes
mA
Minutes
mWhr /
cWhr
mW / cW
Minutes
0.1°K
Counts
%
% / num
mAh
HEX#
mA
SEALED
ACCESS
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Control(): 0x00/0x01
Issuing a Control() command requires a subsequent 2-byte subcommand. These additional bytes specify the
particular control function desired. The Control() command allows the system to control specific features of the
bq28z560-R1 during normal operation and additional features when the bq28z560-R1 is in different access
modes, as described in Table 4.
CNTL FUNCTION
CONTROL_STATUS
DEVICE_TYPE
Table 4. Control() Subcommands
CNTL DATA
0x0000
0x0001
SEALED
ACCESS
Yes
Yes
DESCRIPTION
Reports the status of DF Checksum, Hibernate, IT, etc.
Reports the device type of 0x0541 (indicating bq28z560-R1)
20
Submit Documentation Feedback
Product Folder Links: bq28z560-R1