English
Language : 

DS92LX1621 Datasheet, PDF (13/44 Pages) National Semiconductor (TI) – 10 - 50 MHz Channel Link III Serializer and Deserializer with Embedded Bi-Directional Control Channel
Bi-Directional Control Bus Timing Specifications (SCL, SDA) - (Figure 4)
Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max Units
RECOMMENDED INPUT TIMING REQUIREMENTSRECOMMENDED INPUT TIMING REQUIREMENTS ((Note 13))
fSCL
fLOW
fHIGH
tHD:STA
SCL Clock Frequency
SCL Low Period
SCL High Period
fSCL = 100 kHz
Hold time for a start or a repeated start
condition
>0
100
kHz
4.7
µs
4.0
µs
4.0
µs
tSU:STA
Set Up time for a start or a repeated
start condition
4.7
µs
tHD:DAT Data Hold Time
tSU:DAT Data Set Up Time
tSU:STO Set Up Time for STOP Condition,
tr
SCL & SDA Rise Time
tf
SCL & SDA Fall Time
Cb
Capacitive load for bus
SWITCHING CHARACTERISTICS ((Note 9))
0
3.45
µs
250
ns
4.0
µs
1000
ns
300
ns
400
pF
fSCL
SCL Clock Frequency
Serializer M/S = 0 – R/W Register
0x05 = 0x40'h
Deserializer M/S = 0 – READ
Register 0x06 b[6:4] = 0x00'h
100
kHz
100
Serializer M/S = 0 – R/W Register
0x05 = 0x40'h
fLOW
SCL Low Period
4.7
Deserializer M/S = 0 – READ
μs
Register 0x06 b[6:4] = 0x00'h
Serializer M/S = 0 – R/W Register
0x05 = 0x40'h
fHIGH
SCL High Period
4.0
Deserializer M/S = 0 – READ
μs
Register 0x06 b[6:4] = 0x00'h
tHD:STA
Hold time for a start or a repeated start Serializer M/S = 0 Register 0x05 =
condition
0x40'h
4.0
μs
tSU:STA
Set Up time for a start or a repeated Serializer M/S = 0 Register 0x05 =
start condition
0x40'h
4.7
μs
tHD:DAT
tSU:DAT
tSU:STO
tf
tBUF
Data Hold Time
Data Set Up Time
Set Up Time for STOP Condition
Serializer M/S = 0
SCL & SDA Fall Time
Bus free time between a stop and start Serializer M/S = 0
condition
0
3.45
μs
250
ns
4.0
μs
300
ns
4.7
μs
tTIMEOUT NACK Time out
Serializer M/S = 1
Deserializer MODE = 1
Register 0x06 b[2:0]=111'b
1
ms
25
www.national.com
12