English
Language : 

OPA2333-HT Datasheet, PDF (11/23 Pages) Texas Instruments – 1.8-V MICROPOWER CMOS OPERATIONAL AMPLIFIER ZERO-DRIFT SERIES
OPA2333-HT
www.ti.com
SBOS483F – JULY 2009 – REVISED AUGUST 2012
APPLICATION INFORMATION (1)
The OPA2333 is unity-gain stable and free from unexpected output phase reversal. It uses a proprietary auto-
calibration technique to provide low offset voltage and very low drift over time and temperature. For lowest offset
voltage and precision performance, circuit layout and mechanical conditions should be optimized. Avoid
temperature gradients that create thermoelectric (Seebeck) effects in the thermocouple junctions formed from
connecting dissimilar conductors. These thermally-generated potentials can be made to cancel by ensuring they
are equal on both input terminals. Other layout and design considerations include:
• Use low thermoelectric-coefficient conditions (avoid dissimilar metals)
• Thermally isolate components from power supplies or other heat sources
• Shield op amp and input circuitry from air currents, such as cooling fans
Following these guidelines will reduce the likelihood of junctions being at different temperatures, which can cause
thermoelectric voltages of 0.1 μV/°C or higher, depending on materials used.
Operating Voltage
The OPA2333 op amp operates over a power-supply range of 1.8 V to 5.5 V (±0.9 V to
±2.75 V). Supply voltages higher than 7 V (absolute maximum) can permanently damage the device. Parameters
that vary over supply voltage or temperature are shown in the Typical Characteristics section of this data sheet.
Input Voltage
The OPA2333 input common-mode voltage range extends 0.1 V beyond the supply rails. The OPA2333 is
designed to cover the full range without the troublesome transition region found in some other rail-to-rail
amplifiers.
Normally, input bias current is about 70 pA; however, input voltages exceeding the power supplies can cause
excessive current to flow into or out of the input pins. Momentary voltages greater than the power supply can be
tolerated if the input current is limited to 10 mA. This limitation is easily accomplished with an input resistor(see
Figure 2).
Current- limiting resistor
required if input voltage
exceeds supply rails by
≥ 0.5V.
IOVERLOAD
10mA max
VIN
5kΩ
+5V
OPA2333
VOUT
Figure 2. Input Current Protection
Internal Offset Correction
The OPA2333 op amp uses an auto-calibration technique with a time-continuous 350-kHz op amp in the signal
path. This amplifier is zero corrected every 8 μs using a proprietary technique. Upon power up, the amplifier
requires approximately 100 μs to achieve specified VOS accuracy. This design has no aliasing or flicker noise.
(1) At TA = 25°C (unless otherwise noted).
Copyright © 2009–2012, Texas Instruments Incorporated
Product Folder Links: OPA2333-HT
Submit Documentation Feedback
11