English
Language : 

TLK1221 Datasheet, PDF (8/23 Pages) Texas Instruments – ETHERNET TRANSCEIVER
TLK1221
SLLS713 – FEBRUARY 2007
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VDD,
VDDA,
VDDPLL
IDD, IDDA,
IDDPLL
PD
IDDQ
PLL
Supply voltage
Total supply current
Total power dissipation
Total shutdown current (IDD+IDDA +
IDDPLL )
Startup lock time
TA
Operating free-air temperature
Frequency = 1.25 Gbps, PRBS pattern; ENABLE
= 1, VDD , VDDPLL and VDDA = 2.7 V
Frequency = 1.25 Gbps, PRBS pattern
Enable = 0; VDD , VDDPLL and VDDA = 2.7 V
VDD, VDDA = 2.5 V
REFERENCE CLOCK (REFCLK) TIMING REQUIREMENTS
over recommended operating conditions (unless otherwise noted)
PARAMETER
f
Frequency
Accuracy
DC Duty cycle
Jitter
TEST CONDITIONS
Minimum data rate
Maximum data rate
Random plus deterministic
MIN
TYP – 0.01%
TYP – 0.01%
–100
40%
www.ti.com
MIN NOM MAX UNIT
2.3
2.5
2.7 V
113 mA
235
305 mW
1000 µA
500 µs
–40
85 °C
TYP
60
130
50%
MAX
TYP + 0.01%
TYP + 0.01%
100
60%
40
UNIT
MHz
ppm
ps
TTL ELECTRICAL CHARACTERISTICS
over recommended operating conditions (unless otherwise noted)
PARAMETER
VOH
High-level output voltage
VOL
Low-level output voltage
VIH
High-level input voltage
VIL
Low-level input voltage
IIH
High-level input current
IIL
Low-level input current
CIN
Input capacitance
TEST CONDITIONS
IOH = –400 µA
IOL = 1 mA
VDD = 2.3 V, VIN = 2 V
VDD = 2.3 V, VIN = 0.4 V
MIN
VDD – 0.2
GND
1.7
–40
TYP
MAX UNIT
2.3
V
0.25
0.5
V
3.6
V
0.8
V
40
µA
µA
4
pF
8
Submit Documentation Feedback