English
Language : 

BQ24751RHDRG4 Datasheet, PDF (8/38 Pages) Texas Instruments – Host-controlled Multi-chemistry Battery Charger
bq24751
SLUS734D – DECEMBER 2006 – REVISED MARCH 2009............................................................................................................................................... www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
7.0 V ≤ VPVCC ≤ 24 V, 0°C < TJ < +125°C, typical values are at TA = 25°C, with respect to AGND (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
ACN / BAT COMPARATOR
VACN-BAT_FALL
VACN-BAT_HYS
ACN to BAT falling threshold
ACN to BAT hysteresis
ACN to BAT rising deglitch
ACN to BAT falling deglitch
BAT OVERVOLTAGE COMPARATOR
VACN – VBAT to turn on BATDRV
VACN – VBAT > VACN-BAT_RISE
VACN – VBAT < VACN-BAT_FALL
175 285
50
20
6
340 mV
mV
µs
µs
VOV_RISE
Overvoltage rising threshold
VOV_FALL
Overvoltage falling threshold
BAT SHORT (UNDERVOLTAGE) COMPARATOR
As percentage of VBAT_REG
As percentage of VBAT_REG
104
%
102
VBAT_SHORT_FALL
VBAT_SHORT_HYS
BAT short falling threshold
BAT short hysteresis
BAT short rising deglitch
BAT short falling deglitch
CHARGE OVERCURRENT COMPARATOR
VBAT > VBAT_SHORT+VBAT_SHORT_HYS
Detection delay
VBAT < VBAT_SHORT
2.755 2.9
250
1.5
1.5
3.045 V/cell
mV/cell
s
VOC
Charge over-current falling threshold As percentage of IREG_CHG
Minimum Current Limit (SRP-SRN)
145
%
50
mV
CHARGE UNDERCURRENT COMPARATOR (SYNCHRONOUS TO NON-SYNCHRONOUS TRANSITION)
VISYNSET_FALL
Charge undercurrent falling threshold
Changing from synchronous to
non-sysnchronous
9.75 13 16.25 mV
VISYNSET_HYS
Charge undercurrent rising hysteresis
Charge undercurrent, falling-current
deglitch
Charge undercurrent, rising-current
deglitch
VIREG_DPM < VISYNSET
8
mV
20
µs
640
INPUT OVER-POWER COMPARATOR (ACOP)
VACOC
ACOC Gain for initial ACOC current
limit (Percentage of programmed
VIREG_DPM)
Begins 700 ms after ACDET
Input current limited to this threshold for
fault protection
%
150
VIREG_DPM
VACOC_CEILING
Maximum ACOC input current limit
(VACP–VACN)max
Internally limited ceiling
VACOC_MAX = (VACP–VACN)max
100
mV
ACOP Latch Blankout Time with
ACOC active
(begins 700 ms after ACDET)
Begins 700 ms after ACDET
(does not allow ACOP latch-off, and no
ACOP source current)
2
ms
VACOP
ACOP pin latch-off threshold voltage
(See ACOP in Terminal Functions
table)
1.95
2
2.05
V
KACOP
IACOP_SINK
Gain for ACOP Source Current when
in ACOC
ACOP Sink Current when not in
ACOC
ACOP Latch is reset by going below
ACDET or UVLO
Current source on when in ACOC limit.
Function of voltage across power FET
IACOP_SOURCE = KACOP ×(VPVCC -VACP)
Current sink on when not in ACOC
18
µA / V
µA
5
8
Submit Documentation Feedback
Product Folder Link(s) :bq24751