RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
PH
PVCC, ACP, ACN, SRP, SRN, BAT, BATDRV, ACDRV
REGN, LODRV
VDAC, IADAPT
Voltage range
VREF
ACSET, SRSET, TS, ACDET, ACOP, CHGEN, CELLS, ACGOOD,
LEARN, OVPSET
VADJ
BTST, HIDRV with respect to AGND and PGND
AGND, PGND
Maximum difference
voltage
ACP–ACN, SRP–SRN
Junction temperature range, TJ
Storage temperature range, Tstg
MIN NOM MAX UNIT
–1
24
0
24
0
6.5
0
3.6
3.3
V
0
5.5
0
6.5
0
30
–0.3
0.3
–0.3
0.3 V
–55
125 °C
–40
150 °C
ELECTRICAL CHARACTERISTICS
7.0 V ≤ VPVCC ≤ 24 V, 0°C < TJ < +125°C, typical values are at TA = 25°C, with respect to AGND (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
OPERATING CONDITIONS
VPVCC_OP
PVCC Input voltage operating range
CHARGE VOLTAGE REGULATION
5.0
24.0
V
VBAT_REG_RNG
VVDAC_OP
VADJ_OP
BAT voltage regulation range
VDAC reference voltage range
VADJ voltage range
4-4.512 V per cell, times 2,3,4 cells
8 V, 8.4 V, 9.024 V
8
2.6
0
–0.5%
18.048
V
3.6
V
REGN
V
0.5%
Charge voltage regulation accuracy 12 V, 12.6 V, 13.536 V
–0.5%
0.5%
16 V, 16.8 V, 18.048 V
–0.5%
0.5%
Charge voltage regulation set to
default to 4.2 V per cell
VADJ connected to REGN, 8.4 V, 12.6 V,
16.8 V
–0.5%
0.5%
CHARGE CURRENT REGULATION
VIREG_CHG
Charge current regulation differential VIREG_CHG = VSRP – VSRN
voltage range
0
100 mV
VSRSET_OP
SRSET voltage range
Charge current regulation accuracy
VIREG_CHG = 40–100 mV
VIREG_CHG = 20 mV
VIREG_CHG = 5 mV
VIREG_CHG = 1.5 mV (VBAT>4V)
0
VDAC
V
–3
3
–5
5
%
–25
25
–33
33
6
Submit Documentation Feedback
Product Folder Link(s) :bq24751