English
Language : 

TLC34058-110M Datasheet, PDF (6/21 Pages) Texas Instruments – 256 x 24 COLOR PALETTE
TLC34058-110M
256 × 24 COLOR PALETTE
SGLS075 – JANUARY 1994
Terminal Functions (Continued)
TERMINAL
NAME
NO.† I/O
DESCRIPTION
R/W
36
I Read/write input. This TTL-compatible control input is latched on the falling edge of CE (see Figure 1). When
low, R/W writes data to the device. Data is internally latched on the rising edge of CE. When high, R/W reads
data from the device.
SYNC
68
I Composite sync control input. This TTL-compatible SYNC input is stored in the input latch on the rising edge
of LD. When low, SYNC turns off a 40 IRE current source on the IOG output (see Figure 3). This input does
not override any control data input (see Table 6). It should be brought low during the blanking interval only (see
Figure 3). When high, SYNC allows the device to perform in the standard manner.
VDD
33, 37,
45, 47,
73, 74
Supply voltage. All VDD terminals must be connected together.
† Terminal numbers shown are for the HFG package only. For the GA package terminal assignments, see page 3.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Voltage range on any digital input (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 5 V to VDD + 0.5 V
Analog output short-circuit current to any power supply or common, IOS . . . . . . . . . . . . . . . . . . . . . . unlimited
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions beyond those indicated in the recommended operating conditions section of
this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
recommended operating conditions
Supply voltage, VDD
High-level Input voltage, VIH
Low-level Input voltage, VIL
Reference voltage, Vref
Output load resistance, RL
FS ADJ resistor, Rset
Operating free-air temperature, TA
CLK, CLK
Other inputs
CLK, CLK
Other inputs
MIN
4.5
VDD – 1
2
– 0.5
– 0.5
1.2
– 55
NOM
MAX
5
5.5
VDD + 0.5
VDD + 0.5
VDD – 1.6
0.8
1.235
1.26
37.5
523
125
UNIT
V
V
V
V
V
V
Ω
Ω
°C
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443