RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
SW
PVCC, ACP, ACN, CSP, CSN, BAT
REGN, LODRV
Voltage range
VREF
VDAC
VADJ, ACSET, ISET, ACDET, FSET, IADAPT, LPMOD, LPREF, CE, CELLS,
EXTPWR, DPMDET, TRICKLE
BTST, HIDRV with respect to AGND and PGND
AGND, PGND
Maximum difference voltage: ACP–ACN, CSP–CSN
Junction temperature range
Storage temperature range
www.ti.com
MIN NOM MAX UNIT
–0.8
24 V
0
24 V
0
6.5 V
3.3
V
3.6
V
0
5.5 V
0
30 V
–0.3
0.3 V
–0.3
0.3 V
–40
125 °C
–55
150 °C
ELECTRICAL CHARACTERISTICS
9.0 V ≤ VPVCC ≤ 24 V, 0°C < TJ < +125°C, Fs=600 kHz, typical values are at TA = 25°C, with respect to AGND (unless
otherwise noted) (1) (2) (3)
PARAMETER
TEST CONDITIONS
OPERATING CONDITIONS
VPVCC_OP
PVCC input voltage operating range
CHARGE VOLTAGE REGULATION
VBAT_REG_RNG
VVDAC_OP
VVADJ_OP
BAT voltage regulation range
VDAC reference voltage range
VADJ voltage range
4-4.512 V per cell, times 2,3,4 cells
8 V, 8.4 V, 9.024 V
Charge voltage regulation accuracy
12 V, 12.6 V, 13.536 V
16 V, 16.8 V, 18.048 V
CHARGE CURRENT REGULATION (ENABLE CE & DISABLE TRICKLE)
VIREG_CHG
Charge current regulation differential
voltage range
VIREG_CHG = VCSP – VCSN
VISET_OP
SRSET voltage range
VIREG_CHG = 40 mV
VIREG_CHG = 20 mV
Charge current regulation accuracy
VIREG_CHG = 5 mV
VIREG_CHG = 3 mV (VBAT ≥ 4 V)
VIREG_CHG = 3 mV (VBAT < 4 V)
Off-set Voltage of Amplifier
VBAT ≥ 4 V
VBAT < 4 V
TRICKLE CHARGE CURRENT REGULATION (ENABLE CE & TRICKLE)
Charge Current Regulation Accuracy
Off-set Voltage of Amplifier
VIREG_CHG = 3 mV
MIN TYP MAX UNIT
9
24
V
8
18.048
V
2.6
3.6
V
0
VDAC
V
–0.5
0.5
–0.5
0.5 %
–0.5
0.5
0
0
–3%
–5%
–25%
–33%
–50%
–1.0
–1.5
100 mV
VDAC
V
3%
5%
25%
33%
50%
1.0
mV
1.5
–33%
–1.0
33%
1.0 mV
(1) Verified by design
(2) Deglitch time and delay are proportional to the period of oscillator, unless specified.
(3) When CE=HIGH, the internal oscillator frequency is equal to external setting Fs; when CE=LOW, the internal oscillator frequency is fixed
internal setting 700 kHz.