English
Language : 

TLC6C5712-Q1_15 Datasheet, PDF (38/64 Pages) Texas Instruments – TLC6C5712-Q1 12-Channel, Full-Diagnostic, Constant-Current-Sink LED Driver With 8-Bit Dot Correction
TLC6C5712-Q1
SLVSCO9A – AUGUST 2015 – REVISED AUGUST 2015
7.5.33 WRITE_ERROR_MASK Register (address = 66h) [reset = 00h]
www.ti.com
Figure 55. WRITE_ERROR_MASK Register, Address 66h
7
REF_MASK
6
POR_MASK
5
4
3
OPEN_MASK SHORT_MASK PWM_MASK
R/W
R/W
R/W
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
2
WLS_MASK
R/W
1
PRE_TSD_
MASK
R/W
0
TSD_MASK
R/W
Table 35. WRITE_ERROR_MASK Field Descriptions
Bit Field
7
REF_MASK
6
POR_MASK
5
OPEN_MASK
4
SHORT_MASK
3
PWM_MASK
2
WLS_MASK
1
PRE_TSD_MASK
0
TSD_MASK
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0h
0h
0h
0h
0h
0h
0h
0h
Description
Reference fault mask bit. Active-high. HIGH: Reference fault is
masked; LOW: Reference fault is not masked.
Power-on-reset fault mask bit Active-high. HIGH: POR fault is
masked; LOW: POR fault is not masked.
Open fault mask bit. Active-high. HIGH: Open fault is masked;
LOW: Open fault is not masked.
Short fault mask bit. Active-high. HIGH: Short fault is masked;
LOW: Short fault is not masked.
PWM fault mask bit. Active-high. HIGH: PWM fault is masked;
LOW: PWM fault is not masked.
Weak-LED-supply (WLS) fault mask bit. Active-high. HIGH: WLS
fault is masked; LOW: WLS fault is not masked.
Pre-thermal-warning fault mask bit. Active-high. HIGH:
PRE_TSD fault is masked; LOW: PRE_TSD fault is not masked.
Thermal-shutdown fault mask bit. Active-high. HIGH: TSD fault
is masked; LOW: TSD fault is not masked.
7.5.34 WRITE_MISC_CMD Register (address = 67h) [reset = 00h]
Figure 56. WRITE_MISC_CMD Register, Address 67h
7
6
5
4
RESERVED
DIS_OFF_
FAULT_DIAG
R
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
3
ADJ_DIAG_
START
R/W
2
SLOW_SLEW_
RATE
R/W
1
FORCE_ERR
R/W
0
WLS_TH
R/W
Table 36. WRITE_MISC_CMD Field Descriptions
Bit Field
7–5 RESERVED
4
DIS_OFF_FAULT_DIAG
3
ADJ_DIAG_START
2
SLOW_SLEW_RATE
1
FORCE_ERR
0
WLS_TH
Type
R
R/W
Reset
0h
0h
R/W
0h
R/W
0h
R/W
0h
R/W
0h
Description
Off-state output fault diagnostics control bit. Active-high. HIGH:
Off-state fault diagnostics disabled; LOW: Off-state fault
diagnostics enabled
Adjacent-pin diagnostics start control bit. Active-high, returns low
when adjacent-pin diagnostic procedure is concluded.
HIGH: Start adjacent-pin diagnostics or adjacent-pin diagnostics
are ongoing; LOW: Adjacent-pin diagnostics are not running.
Slow slew rate control bit. Active-high. HIGH: Output-current
slew rate is in slow mode. LOW: Output-current slew rate is in
normal mode.
Force error control bit. Active-high. HIGH: ERR output is forced
low. LOW: ERR output is not forced low.
Weak-LED-supply threshold-control bit. Active-high. HIGH: WLS
threshold is set to 3.3-V mode. LOW: WLS threshold is set to 5-
V mode.
38
Submit Documentation Feedback
Product Folder Links: TLC6C5712-Q1