English
Language : 

TLC6C5712-Q1_15 Datasheet, PDF (37/64 Pages) Texas Instruments – TLC6C5712-Q1 12-Channel, Full-Diagnostic, Constant-Current-Sink LED Driver With 8-Bit Dot Correction
www.ti.com
TLC6C5712-Q1
SLVSCO9A – AUGUST 2015 – REVISED AUGUST 2015
7.5.32 WRITE_DIS_PULL_UP_1 Register (address = 65h) [reset = 00h]
Figure 54. WRITE_DIS_PULL_UP_1 Register, Address 65h
7
6
5
4
RESERVED
DIS_PULL_UP DIS_PULL_UP
_CH11
_CH10
R
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
3
DIS_PULL_UP
_CH9
R/W
2
DIS_PULL_UP
_CH8
R/W
1
DIS_PULL_UP
_CH7
R/W
0
DIS_PULL_UP
_CH6
R/W
Table 34. WRITE_DIS_PULL_UP_1 Field Descriptions
Bit Field
7–6 RESERVED
5
DIS_PULL_UP_CH11
4
DIS_PULL_UP_CH10
3
DIS_PULL_UP_CH9
2
DIS_PULL_UP_CH8
1
DIS_PULL_UP_CH7
0
DIS_PULL_UP_CH6
Type
R
R/W
Reset
0h
0h
R/W
0h
R/W
0h
R/W
0h
R/W
0h
R/W
0h
Description
Disable deactivated-channel internal pullup register for channel
11. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Disable deactivated-channel internal pullup register for channel
10. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Disable deactivated-channel internal pullup register for channel
9. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Disable deactivated-channel internal pullup register for channel
8. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Disable deactivated-channel internal pullup register for channel
7. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Disable deactivated-channel internal pullup register for channel
6. Active-high. HIGH: internal pullup disabled; LOW: internal
pullup enabled.
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: TLC6C5712-Q1
Submit Documentation Feedback
37