English
Language : 

MSP430X47X3_07 Datasheet, PDF (34/76 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x47x3, MSP430x47x4
MIXED SIGNAL MICROCONTROLLER
SLAS545A − MAY 2007 − REVISED DECEMBER 2007
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted)
DCO
PARAMETER
TEST CONDITIONS
f(DCOCLK)
N(DCO)=01Eh, FN_8=FN_4=FN_3=FN_2=0, D = 2; DCOPLUS= 0
f(DCO=2)
FN_8=FN_4=FN_3=FN_2=0; DCOPLUS = 1
f(DCO=27)
f(DCO=2)
FN_8=FN_4=FN_3=FN_2=0; DCOPLUS = 1
FN_8=FN_4=FN_3=0, FN_2=1; DCOPLUS = 1
f(DCO=27)
FN_8=FN_4=FN_3=0, FN_2=1; DOPLUS = 1
f(DCO=2)
FN_8=FN_4=0, FN_3= 1, FN_2=x; DCOPLUS = 1
f(DCO=27)
FN_8=FN_4=0, FN_3= 1, FN_2=x; DCOPLUS = 1
f(DCO=2)
FN_8=0, FN_4= 1, FN_3= FN_2=x; DCOPLUS = 1
f(DCO=27)
FN_8=0, FN_4=1, FN_3= FN_2=x; DCOPLUS = 1
f(DCO=2)
FN_8=1, FN_4=FN_3=FN_2=x; DCOPLUS = 1
f(DCO=27)
Sn
Dt
DV
FN_8=1,FN_4=FN_3=FN_2=x; DCOPLUS = 1
Step size between adjacent DCO taps:
Sn = fDCO(Tap n+1) / fDCO(Tap n), (see Figure 14 for taps 21 to 27)
Temperature drift, N(DCO) = 01Eh, FN_8=FN_4=FN_3=FN_2=0
D = 2; DCOPLUS = 0
Drift with VCC variation, N(DCO) = 01Eh,
FN_8=FN_4=FN_3=FN_2=0, D= 2; DCOPLUS = 0
VCC = 2.2 V/3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
1 < TAP ≤ 20
TAP = 27
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V/3 V
MIN TYP MAX UNIT
1
MHz
0.3 0.65 1.25
MHz
0.3 0.7 1.3
2.5 5.6 10.5
MHz
2.7 6.1 11.3
0.7 1.3 2.3
MHz
0.8 1.5 2.5
5.7 10.8
6.5 12.1
18
MHz
20
1.2
2
3
MHz
1.3 2.2 3.5
9 15.5
25
10.3 17.9 28.5 MHz
1.8 2.8 4.2
MHz
2.1 3.4 5.2
13.5 21.5
16 26.6
33
MHz
41
2.8 4.2 6.2
MHz
4.2 6.3 9.2
21
32
46
30
46
70 MHz
1.06
1.11
1.07
1.17
–0.2 –0.3 –0.4
%/_C
–0.2 –0.3 –0.4
0
5
15 %/V
f(DCO)
f(DCO3V)
f(DCO)
f(DCO205C)
1.0
1.0
0 1.8
2.4
3.0
3.6
VCC − V
−40 −20
0
20
40
60
Figure 13. DCO Frequency vs Supply Voltage VCC and vs Ambient Temperature
85
TA − °C
34
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265