TLK2501
1.5 TO 2.5 GBPS TRANSCEIVER
SLLS427D − AUGUST 2000 − REVISED JULY 2003
built-in self-test (BIST)
The TLK2501 has a BIST function. By combining PRBS with loopback, an effective self-test of all the circuitry
running at full speed can be realized. The successful completion of the BIST is reported on the
RX_ER/PRBS_PASS terminal.
power-on reset
Upon application of minimum valid power, the TLK2501 generates a power-on reset. During the power-on reset
the RXD, RX_ER, and RX_DV/LOS signal terminals go to a high-impedance state. The RX_CLK is held low.
The length of the power-on reset cycle is dependent upon the REFCLK frequency, but is less than 1 ms.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to 3 V
Voltage range at TXD, ENABLE, GTX_CLK, TX_EN, TX_ER, LOOPEN, PRBSEN, LCKREFN . . . −0.3 to 4 V
Voltage range at any other terminal except above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to VDD+0.3 V
Package power dissipation, PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Storage temperature, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HBM:3 KV, CDM:1.5 KV
Characterized free-air operating temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential I/O bus voltages, are with respect to network ground.
DISSIPATION RATING TABLE
PACKAGE
RCP64§
TA ≤ 2 5_C
POWER RATING
5.25 W
DERATING FACTOR‡
ABOVE TA = 25_C
46.58 mW/_C
RCP64¶
3.17 W
23.70 mW/_C
RCP64#
2.01 W
13.19 mW/_C
‡ This is the inverse of the traditional junction-to-ambient thermal resistance (RθJA).
§ 2 oz. Trace and copper pad with solder.
¶ 2 oz. Trace and copper pad without solder.
# Standard JEDEC High-K board.
TA = 70_C
POWER RATING
2.89 W
1.74 W
1.11 W
For more information, refer to TI application note PowerPAD Thermally Enhanced Package, TI literature
number SLMA002.
electrical characteristics over recommended operating conditions
PARAMETER
TEST CONDITIONS
Supply voltage, VDD
Supply current, ICC
Power dissipation, PD
Shutdown current
PLL startup lock time
Data acquisition time
VDD = 2.5 V, Frequency = 1.5 Gbps, PRBS pattern
VDD = 2.5 V, Frequency = 2.5 Gbps, PRBS pattern
VDD = 2.5 V, Frequency = 1.5 Gbps, PRBS pattern
VDD = 2.5 V, Frequency = 2.5 Gbps, PRBS pattern
VDD = 2.7 V, Frequency = 2.5 Gbps, worst case pattern||
Enable = 0, VDDA + VDD terminals = max
VDD,VDDA = 2.3V, EN ↑ to PLL acquire
Operating free-air temperature, TA
|| Worst case pattern is a pattern that creates a maximum transition density on the serial transceiver.
MIN NOM
2.3 2.5
105
145
262
362
20
0.1
1024
−40
MAX
2.7
500
0.4
85
UNIT
V
mA
mW
mW
mW
mA
ms
bits
°C
14
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265