English
Language : 

DRV3204-Q1_15 Datasheet, PDF (14/38 Pages) Texas Instruments – Three-Phase Brushless Motor Driver
DRV3204-Q1
SLVSBT3B – MARCH 2013 – REVISED JULY 2013
FLGFLT1 (address 0x09): Fault Flag Register 1
Bit
Name
Type (1)
Reset Description
7:1 RSVD R
0
VBUV RW
0000
000
1
Reserved
Fault flag bit of thermal shutdown condition.(2)
If FLTCFG.FLGLATCH_EN = 1
0: Read = No fault condition exists since last cleared.
Write = No effect
1: Read = Fault condition exists.
Write = Clear the flag
If FLTCFG.FLGLATCH_EN = 0
0: Read = No fault condition
Write = No effect
1: Read = Fault condition
Write = No effect
(1) R: Read, W: Write
(2) Assertion of the fault flags may occur during power up.
CS
SCK
Fault Event
SPI Read Buffer
Status N
Status N+1
Status N
Status N+1
SPI DOUT
FLTFLG*
Status N
Serial Output Format
FLTFLG*
Status N+1
Serial Output Format
Figure 8. SPI Data-Out Timing Chart of Fault Flag Registers
www.ti.com
14
Submit Documentation Feedback
Product Folder Links :DRV3204-Q1
Copyright © 2013, Texas Instruments Incorporated