Table 1 : Acceptance criteria and number of tests.
TEST ACCEPTANCE NUMBER TO TESTS
CRITERIA
2
A
10 for longitudinal A
10 for longitudinal B
and 10 for transversal
3a
A
5
3b
B
1
3
B
1 for each position of s
CLP200M
Fig. 15 : CLP200M response to a negative surge.
3.2. Ringing mode
Figures 14 and 15 show that the remaining
overvoltage does not exceed +/- 260 V. The
3.2.1. Lightning simulation test
CLP200M switches on within 0.7 µs and with-
Lightning phenomena are the most common surge
t(s) causes. The purpose of this test is to check the ro-
bustness of the CLP200M against these lightning
c strikes.
rodu Fig. 13 : Lightning simulation test.
lete P 10/700µs
o GENERATOR
bs +/- 4kV
I
4Ω
Rsense
Rp
TIPL
TIPS
1/2 CLP200M
GND
V
stands the 100 A given by the CCITT K20 genera-
tor.
Consequently, the CLP200M totally fulfills this test.
3.2.2 Power induction
(Test 3a and 3b table 2/K20)
Surges of long duration with medium voltage value
are mainly produced by the proximity of a sub-
scriber line with an AC mains line or equipment.
The purpose of this test is to check the robustness
of the CLP200M against these capacitive coupling
disturbances.
Fig. 16 : Power inductance test.
ct(s) - O Fig. 14 : CLP200M response to a positive surge.
te Produ TEST
ole 3a
Obs 3b
V(RMS)
300
300
R(Ω)
600
200
Duration
0.2s
?
9/21