English
Language : 

CLP200M_03 Datasheet, PDF (10/21 Pages) STMicroelectronics – OVERVOLTAGE AND OVERCURRENT PROTECTION FOR TELECOM LINE
CLP200M
Fig. 17 : CLP200M response to the induction test
(Test 3a).
The test 3 of CCITT K20 requires a serial PTC (or
fuse) which is inserted in the test circuit to limit the
current rate. This PTC acts like an open-circuit in a
non-instantaneous way when a surge occurs on
the line. Meanwhile, the CLP200M has to with-
stand the surge.
Fig. 19 : Power contact test.
I
600 Ω or < 10 Ω
V(RMS)
PTC
15min
50Hz
4
Rsense
TIPL
TIPS
1/2 CLP200M
GND
Rp
V
Fig. 20 : Power contact test 3 (With 10Ω series).
t(s) Fig. 18 : CLP200M reponse to the induction test
c (Test 3b).
te Product(s) - Obsolete Produ Figures 17 and 18 show that the remaining voltage
does not exceed 270 V.
le Consequently, the CLP200M totally fulfills this test.
so The test duration is not specified in test 3b. If the
bduration exceeds 5s we do suggest to follow the
Osoldering and mounting recommendations given
Figure 20 shows that the remaining overvoltage
does not exceed 250 V and shows that the PTC
acts like an open-circuit after 60 ms.
Consequently, the CLP200M totally fulfills this test.
3.3. Speech mode
3.3.1. Lightning simulation test
(Test 2, table 2/K20)
on page 17 of this document.
Fig. 21: Lightning test in speech mode.
3.2.3 Power contact (Test 3 table 1/K20)
This long duration surge is produced when con-
necting a subscriber line to an AC mains line or
equipment. The purpose of this test is to check the
robustness of the CLP200M against these distur-
bances.
10/700µs
GENERATOR
+/- 4kV
I1
4
Rsense
50
I2
Rp
SLIC
TIPL
TIPS
1/2 CLP200M
GND
V1
-48V
V2
LCP1511D
10/21