English
Language : 

STM8L151X6 Datasheet, PDF (70/146 Pages) STMicroelectronics – Operating conditions
Electrical parameters
STM8L151x6/8 STM8L152x6/8
9.3
9.3.1
Operating conditions
Subject to general operating conditions for VDD and TA.
General operating conditions
Table 18. General operating conditions
Symbol
Parameter
Conditions
Min.
Max.
Unit
fSYSCLK(1)
VDD
VDDA
PD(3)
TA
TJ
System clock
frequency
Standard operating
voltage
Analog operating
voltage
Power dissipation at
TA= 85 °C for suffix 6
devices
Power dissipation at
TA= 125 °C for suffix 3
devices and at
TA= 105 °C for suffix 7
devices
Temperature range
Junction temperature
range
1.65 V ≤VDD < 3.6 V
BOR detector disabled
(D suffix version)
BOR detector enabled
ADC and DAC
not used
ADC or DAC
used
Must be at the same
potential as VDD
LQFP80
LQFP64
UFQFPN48
LQFP48
WLCSP32
LQFP80
LQFP64
UFQFPN48
LQFP48
1.65 V ≤VDD < 3.6 V (6 suffix version)
1.65 V ≤VDD < 3.6 V (7 suffix version)
1.65 V ≤VDD < 3.6 V (3 suffix version)
-40 °C ≤TA < 85 °C
(6 suffix version)
-40 °C ≤ TA < 105 °C
(7 suffix version)
-40 °C≤ TA < 125 °C
(3 suffix version)
0
1.65
1.8(2)
1.65
1.8
-
-
-
-
-
-
-
-
-
-40
-40
-40
-40
-40
-40
16
3.6
3.6
3.6
526
416
625
307
317
131
104
156
77
85
105
125
105
110(4)
130(4)
MHz
V
V
V
mW
°C
1. fSYSCLK = fCPU
2. 1.8 V at power-up, 1.65 V at power-down if BOR is disabled by option byte
3.
To calculate
table.
PDmax(TA),
use
the
formula
PDmax=(TJmax
-TA)/ΘJA
with
TJmax
in
this
table
and
ΘJA
in
“Thermal
characteristics”
4. TJmax is given by the test limit. Above this value the product behavior is not guaranteed.
70/146